Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0375 # 04 Y:2000 | 04 | 2000 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $62,609 | $2,520 | Not Implemented |
WI0375 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,591 | $22,283 | Not Implemented |
WI0375 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $6,364 | $675 | Not Implemented |
WI0375 # 07 Y:2000 | 07 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,097 | $7,825 | Not Implemented |
WI0375 # 08 Y:2000 | 08 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,855 | $500 | Implemented |
WI0375 # 09 Y:2000 | 09 | 2000 | USE OPTIMUM THICKNESS INSULATION | $1,052 | $1,084 | Not Implemented |
WI0375 # 10 Y:2000 | 10 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $969 | $740 | Not Implemented |
WI0375 # 11 Y:2000 | 11 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $957 | $300 | Not Implemented |
WI0375 # 12 Y:2000 | 12 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $395 | $0 | Not Implemented |
NV0150 # 06 Y:2000 | 06 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $885 | $304 | Implemented |
NV0150 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $1,583 | $0 | Not Implemented |
NV0150 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $357 | $100 | Implemented |
NV0150 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $385 | $3,344 | Implemented |
NV0150 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $359 | $105 | Implemented |
NV0150 # 05 Y:2000 | 05 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $13,222 | $10,869 | Not Implemented |
WI0372 # 01 Y:2000 | 01 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $201,600 | $0 | Not Implemented |
WI0372 # 02 Y:2000 | 02 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $36,000 | $0 | Not Implemented |
WI0372 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,349 | $13,911 | Not Implemented |
WI0372 # 04 Y:2000 | 04 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,060 | $0 | Not Implemented |
WI0372 # 05 Y:2000 | 05 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,804 | $2,000 | Not Implemented |
WI0372 # 06 Y:2000 | 06 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,632 | $0 | Not Implemented |
WI0372 # 07 Y:2000 | 07 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $737 | $640 | Not Implemented |
WI0372 # 08 Y:2000 | 08 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $137 | $400 | Not Implemented |
WI0371 # 01 Y:2000 | 01 | 2000 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $24,407 | $25,200 | Not Implemented |
WI0371 # 02 Y:2000 | 02 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,743 | $0 | Implemented |