Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0075 # 02 Y:1983 | 02 | 1983 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $41,500 | $80,000 | Not Implemented |
UD0075 # 03 Y:1983 | 03 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,692 | $0 | Not Implemented |
UD0075 # 04 Y:1983 | 04 | 1983 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $4,855 | $17,600 | Not Implemented |
UD0075 # 05 Y:1983 | 05 | 1983 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,046 | $33,000 | Not Implemented |
UD0075 # 06 Y:1983 | 06 | 1983 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,168 | $400 | Not Implemented |
UD0076 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,494 | $421 | Not Implemented |
UD0076 # 02 Y:1983 | 02 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $427 | $250 | Not Implemented |
UD0076 # 03 Y:1983 | 03 | 1983 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $990 | $438 | Not Implemented |
UD0073 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,488 | $150 | Not Implemented |
UD0073 # 02 Y:1983 | 02 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,396 | $37,500 | Not Implemented |
UD0073 # 03 Y:1983 | 03 | 1983 | AIR CONDITION ONLY SPACE NECESSARY | $356 | $375 | Not Implemented |
OK0070 # 01 Y:1983 | 01 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,791 | $60 | Implemented |
OK0070 # 02 Y:1983 | 02 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $297 | $392 | Implemented |
OK0070 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $163 | $475 | Not Implemented |
OK0070 # 04 Y:1983 | 04 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $197 | $475 | Not Implemented |
OK0070 # 05 Y:1983 | 05 | 1983 | INSTALL SET-BACK TIMERS | $4,660 | $14,963 | Implemented |
OK0070 # 06 Y:1983 | 06 | 1983 | USE RADIANT HEATER FOR SPOT HEATING | $3,156 | $1,000 | Implemented |
OK0070 # 07 Y:1983 | 07 | 1983 | OPTIMIZE PLANT POWER FACTOR | $1,612 | $2,173 | Implemented |
OK0070 # 08 Y:1983 | 08 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,064 | $53,000 | Not Implemented |
OK0058 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $261 | $270 | Implemented |
OK0058 # 02 Y:1982 | 02 | 1982 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $19,472 | $16,000 | Not Implemented |
OK0058 # 03 Y:1982 | 03 | 1982 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $194 | $475 | Implemented |
OK0058 # 04 Y:1982 | 04 | 1982 | USE UTILITY CONTROLLED POWER MANAGEMENT | $365 | $0 | Implemented |
OK0056 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $103 | $0 | Not Implemented |
OK0056 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $2,244 | $726 | Not Implemented |