Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
310
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0244 # 07 Y:1988 | 07 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $178 | $275 | Implemented |
KU0244 # 08 Y:1988 | 08 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $10 | Not Implemented |
KU0244 # 09 Y:1988 | 09 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $114 | $0 | Implemented |
KU0243 # 06 Y:1988 | 06 | 1988 | IMPROVE LUBRICATION PRACTICES | $2,035 | $0 | Implemented |
KU0243 # 05 Y:1988 | 05 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $2,035 | $200 | Implemented |
KU0243 # 04 Y:1988 | 04 | 1988 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $8,090 | $4,000 | Not Implemented |
KU0243 # 03 Y:1988 | 03 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,418 | $4,800 | Implemented |
KU0243 # 02 Y:1988 | 02 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,137 | $20,300 | Not Implemented |
KU0243 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,552 | $9,509 | Not Implemented |
KU0243 # 07 Y:1988 | 07 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,798 | $1,320 | Implemented |
KU0243 # 08 Y:1988 | 08 | 1988 | MINIMIZE WATER USAGE | $1,298 | $1,320 | Not Implemented |
KU0243 # 09 Y:1988 | 09 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $534 | $450 | Implemented |
KU0243 # 10 Y:1988 | 10 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $454 | $0 | Not Implemented |
KU0243 # 11 Y:1988 | 11 | 1988 | USE COMPRESSOR AIR FILTERS | $128 | $0 | Implemented |
OK0223 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,228 | $2,950 | Implemented |
OK0223 # 02 Y:1987 | 02 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $471 | $0 | Implemented |
OK0223 # 03 Y:1987 | 03 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $198 | $123 | Implemented |
OK0223 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $446 | $0 | Implemented |
KU0173 # 04 Y:1985 | 04 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $890 | $20 | Implemented |
KU0173 # 03 Y:1985 | 03 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,053 | $1,000 | Not Implemented |
KU0173 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,042 | $3,793 | Implemented |
KU0173 # 05 Y:1985 | 05 | 1985 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $777 | $200 | Implemented |
KU0173 # 06 Y:1985 | 06 | 1985 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $549 | $1,000 | Not Implemented |
KU0173 # 09 Y:1985 | 09 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $152 | $150 | Not Implemented |
KU0173 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,572 | $1,200 | Not Implemented |