Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsSIC | 2711 | Newspapers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0134 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $445 | $674 | Implemented |
CO0134 # 05 Y:1988 | 05 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $167 | $300 | Not Implemented |
CO0134 # 04 Y:1988 | 04 | 1988 | INSTALL SET-BACK TIMERS | $779 | $800 | Not Implemented |
CO0134 # 03 Y:1988 | 03 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $455 | $421 | Implemented |
CO0134 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $790 | $1,162 | Implemented |
CO0134 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $211 | $200 | Not Implemented |
CO0132 # 02 Y:1988 | 02 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,629 | $250 | Not Implemented |
CO0132 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $625 | $580 | Implemented |
CO0132 # 05 Y:1988 | 05 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $249 | $300 | Implemented |
CO0132 # 04 Y:1988 | 04 | 1988 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $567 | $460 | Not Implemented |
CO0132 # 03 Y:1988 | 03 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,170 | $600 | Implemented |
CO0132 # 01 Y:1988 | 01 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,251 | $250 | Implemented |
OK0246 # 01 Y:1988 | 01 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $2,000 | $0 | Implemented |
OK0246 # 02 Y:1988 | 02 | 1988 | REDUCE VENTILATION AIR | $7,120 | $0 | Implemented |
OK0246 # 03 Y:1988 | 03 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,483 | $300 | Not Implemented |
OK0246 # 04 Y:1988 | 04 | 1988 | REDUCE VENTILATION AIR | $6,835 | $0 | Implemented |
OK0246 # 05 Y:1988 | 05 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $180 | $155 | Implemented |
OK0246 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,414 | $1,880 | Not Implemented |
OK0246 # 07 Y:1988 | 07 | 1988 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $395 | $620 | Not Implemented |