Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 273 | Books |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0244 # 09 Y:1988 | 09 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $114 | $0 | Implemented |
KU0244 # 08 Y:1988 | 08 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $10 | Not Implemented |
KU0244 # 07 Y:1988 | 07 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $178 | $275 | Implemented |
KU0244 # 06 Y:1988 | 06 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $324 | $0 | Implemented |
KU0244 # 05 Y:1988 | 05 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $404 | $125 | Implemented |
KU0244 # 04 Y:1988 | 04 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,359 | $2,400 | Implemented |
KU0244 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,442 | $9,509 | Implemented |
KU0244 # 02 Y:1988 | 02 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,665 | $0 | Implemented |
KU0244 # 03 Y:1988 | 03 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,434 | $2,355 | Not Implemented |
KU0137 # 09 Y:1984 | 09 | 1984 | INSULATE BARE EQUIPMENT | $754 | $750 | Not Implemented |
KU0137 # 04 Y:1984 | 04 | 1984 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $250 | $90 | Not Implemented |
KU0137 # 07 Y:1984 | 07 | 1984 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,169 | $400 | Not Implemented |
KU0137 # 06 Y:1984 | 06 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,472 | $2,000 | Not Implemented |
KU0137 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,930 | $0 | Implemented |
KU0137 # 01 Y:1984 | 01 | 1984 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $4,772 | $4,500 | Not Implemented |
KU0137 # 02 Y:1984 | 02 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $3,839 | $0 | Implemented |
KU0137 # 03 Y:1984 | 03 | 1984 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,293 | $0 | Not Implemented |
KU0137 # 12 Y:1984 | 12 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $235 | $50 | Implemented |
KU0137 # 08 Y:1984 | 08 | 1984 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $1,200 | $1,670 | Not Implemented |
KU0137 # 10 Y:1984 | 10 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $471 | $20 | Not Implemented |
KU0137 # 13 Y:1984 | 13 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $212 | $0 | Not Implemented |
KU0137 # 14 Y:1984 | 14 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $118 | $0 | Implemented |
KU0137 # 15 Y:1984 | 15 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $118 | $40 | Not Implemented |
KU0057 # 06 Y:1982 | 06 | 1982 | INSTALL AUTOMATIC STACK DAMPER | $135 | $275 | Implemented |
KU0057 # 05 Y:1982 | 05 | 1982 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $296 | $0 | Implemented |