Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
SIC 2752 Commercial Printing, Lithographic
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0370 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $767 $578 Implemented
DL0077 # 05 Y:2011 05 2011 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $21,318 $1,600 Implemented
DL0077 # 02 Y:2011 02 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $119,680 $350,000 Implemented
DL0077 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,771 $11,600 Implemented
SU0281 # 01 Y:2009 01 2009 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $8,503 $0 Implemented
SU0281 # 13 Y:2009 13 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,072 $4,000 Implemented
SU0281 # 12 Y:2009 12 2009 INSTALL OCCUPANCY SENSORS $241 $516 Implemented
SU0281 # 11 Y:2009 11 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,300 $5,580 Implemented
SU0281 # 09 Y:2009 09 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $408 $589 Implemented
SU0281 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $712 $720 Implemented
SU0281 # 07 Y:2009 07 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $400 $90 Implemented
SU0281 # 06 Y:2009 06 2009 REPAIR AND ELIMINATE STEAM LEAKS $3,172 $53 Implemented
SU0281 # 05 Y:2009 05 2009 USE SYNTHETIC LUBRICANT $48 $0 Implemented
SU0281 # 04 Y:2009 04 2009 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $248 $0 Implemented
SU0281 # 02 Y:2009 02 2009 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,848 $0 Implemented
SU0186 # 09 Y:2004 09 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,324 $1,305 Implemented
SU0186 # 08 Y:2004 08 2004 USE SYNTHETIC LUBRICANT $1,467 $1,000 Implemented
SU0186 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $236 $154 Implemented
SU0186 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,635 $400 Implemented
SU0186 # 03 Y:2004 03 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,485 $1,693 Implemented
SU0186 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $12,704 $0 Implemented
HO0184 # 08 Y:1998 08 1998 $4,469 $200 Implemented
HO0184 # 06 Y:1998 06 1998 MAINTAIN MACHINES TO REDUCE LEAKS $360 $100 Implemented
HO0184 # 05 Y:1998 05 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,835 $0 Implemented
HO0184 # 02 Y:1998 02 1998 KEEP LAMPS AND REFLECTORS CLEAN $1,669 $0 Implemented