IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,202

matching recommendations
Reset
SIC 2759 Commercial Printing, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0437 # 04 Y:2017 04 2017 REDUCE VENTILATION AIR $1,161 $905 Not Implemented
SU0437 # 05 Y:2017 05 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $995 $820 Not Implemented
SU0437 # 06 Y:2017 06 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,897 $5,500 Not Implemented
SU0437 # 07 Y:2017 07 2017 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $175 $358 Not Implemented
WM0101 # 01 Y:2017 01 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,590 $22,000 Not Implemented
WM0101 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,976 $25,932 Not Implemented
WM0101 # 03 Y:2017 03 2017 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,523 $260 Not Implemented
WM0101 # 04 Y:2017 04 2017 INSTALL OCCUPANCY SENSORS $2,778 $1,590 Not Implemented
WM0101 # 05 Y:2017 05 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,320 $6,300 Not Implemented
WM0101 # 06 Y:2017 06 2017 USE PHOTOCELL CONTROLS $545 $885 Not Implemented
WM0101 # 07 Y:2017 07 2017 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $251 $200 Implemented
WM0101 # 08 Y:2017 08 2017 SHADE WINDOWS FROM SUMMER SUN $245 $210 Not Implemented
LE0424 # 01 Y:2016 01 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,742 $1,000 Implemented
LE0424 # 02 Y:2016 02 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,378 $600 Implemented
LE0424 # 03 Y:2016 03 2016 RECOVER WASTE HEAT FROM EQUIPMENT $7,795 $2,750 Implemented
LE0424 # 04 Y:2016 04 2016 INSTALL OCCUPANCY SENSORS $825 $500 Not Implemented
LE0424 # 05 Y:2016 05 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,065 $3,420 Implemented
LE0424 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $760 $3,440 Not Implemented
WM0085 # 01 Y:2016 01 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,524 $28,800 Not Implemented
WM0085 # 02 Y:2016 02 2016 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $3,682 $2,500 Not Implemented
WM0085 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $912 $1,520 Not Implemented
WM0085 # 04 Y:2016 04 2016 REPAIR AND ELIMINATE STEAM LEAKS $696 $180 Implemented
DL0163 # 01 Y:2016 01 2016 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $30,630 $2,700 Implemented
DL0163 # 02 Y:2016 02 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,570 $200 Not Implemented
DL0163 # 03 Y:2016 03 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,160 $7,000 Not Implemented