Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
SIC 2759 Commercial Printing, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0163 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,110 $55,940 Implemented
DL0163 # 03 Y:2016 03 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,160 $7,000 Not Implemented
DL0163 # 02 Y:2016 02 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,570 $200 Not Implemented
DL0163 # 01 Y:2016 01 2016 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $30,630 $2,700 Implemented
DL0051 # 02 Y:2010 02 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $573 $0 Implemented
DL0051 # 01 Y:2010 01 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,124 $0 Implemented
DL0051 # 09 Y:2010 09 2010 REPLACE BOILER $6,600 $16,743 Implemented
DL0051 # 08 Y:2010 08 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,720 $20,796 Not Implemented
DL0051 # 07 Y:2010 07 2010 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION $4,473 $3,840 Not Implemented
DL0051 # 06 Y:2010 06 2010 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $4,250 $960 Not Implemented
DL0051 # 05 Y:2010 05 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $860 $150 Not Implemented
DL0051 # 04 Y:2010 04 2010 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,500 $100 Implemented
DL0051 # 03 Y:2010 03 2010 USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS $940 $30 Implemented
WV0352 # 01 Y:2006 01 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,713 $170 Implemented
WV0352 # 10 Y:2006 10 2006 UTILIZE A LESS EXPENSIVE COOLING METHOD $473 $325 Not Implemented
WV0352 # 11 Y:2006 11 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $460 $735 Not Implemented
WV0352 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,003 $15,353 Not Implemented
WV0352 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,241 $1,335 Implemented
WV0352 # 08 Y:2006 08 2006 INSTALL OCCUPANCY SENSORS $857 $700 Not Implemented
WV0352 # 09 Y:2006 09 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $702 $13 Not Implemented
WV0352 # 07 Y:2006 07 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $857 $25 Not Implemented
WV0352 # 03 Y:2006 03 2006 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,862 $3,440 Implemented
WV0352 # 04 Y:2006 04 2006 DISCONNECT BALLASTS $1,803 $1,500 Implemented
WV0352 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,773 $1,431 Implemented
WV0352 # 12 Y:2006 12 2006 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $325 $38 Not Implemented