Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
308
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0209 # 10 Y:2001 | 10 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $10,653 | $8,000 | Implemented |
WV0209 # 11 Y:2001 | 11 | 2001 | RECOVER AND REUSE COOLING WATER | $10,000 | $8,150 | Not Implemented |
WV0209 # 12 Y:2001 | 12 | 2001 | REUSE SCRAP GLASS AS FEED STOCK | $40 | $0 | Implemented |
WV0209 # 13 Y:2001 | 13 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $140 | $50 | Implemented |
WV0209 # 14 Y:2001 | 14 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $34,833 | $17,500 | Not Implemented |
HO0188 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,465 | $5,432 | Implemented |
HO0188 # 02 Y:1998 | 02 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,007 | $4,000 | Not Implemented |
HO0188 # 03 Y:1998 | 03 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,536 | $1,376 | Implemented |
HO0188 # 04 Y:1998 | 04 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,904 | $27,000 | Not Implemented |
HO0188 # 05 Y:1998 | 05 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $500 | $1,000 | Not Implemented |
WV0116 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,254 | $439 | Implemented |
WV0116 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $220 | $600 | Not Implemented |
WV0116 # 03 Y:1997 | 03 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,312 | $2,000 | Implemented |
WV0116 # 04 Y:1997 | 04 | 1997 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,636 | $11,600 | Not Implemented |
WV0116 # 05 Y:1997 | 05 | 1997 | INSULATE BARE EQUIPMENT | $262 | $268 | Implemented |
WV0116 # 06 Y:1997 | 06 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,025 | $0 | Implemented |
WV0116 # 07 Y:1997 | 07 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $25,500 | $5,000 | Not Implemented |
WV0116 # 08 Y:1997 | 08 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $189,000 | $2,360 | Not Implemented |
WV0100 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,071 | $261 | Implemented |
WV0100 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $256 | $573 | Implemented |
WV0100 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $207 | $30 | Implemented |
WV0100 # 04 Y:1996 | 04 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $753 | $4,725 | Not Implemented |
WV0100 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,817 | $0 | Not Implemented |
WV0100 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $1,680 | $2,290 | Implemented |
WV0100 # 07 Y:1996 | 07 | 1996 | INSULATE BARE EQUIPMENT | $545 | $656 | Not Implemented |