Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 2821 | Plastics Materials And Resins |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0148 # 09 Y:1999 | 09 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $12,122 | $100 | Implemented |
MS0148 # 08 Y:1999 | 08 | 1999 | BURN WASTE OIL FOR HEAT | $614 | $2,274 | Not Implemented |
MS0148 # 07 Y:1999 | 07 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,552 | $18,900 | Not Implemented |
MS0148 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,282 | $2,577 | Not Implemented |
MS0148 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,136 | $1,500 | Implemented |
MS0148 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $374 | $222 | Not Implemented |
MS0148 # 03 Y:1999 | 03 | 1999 | USE PHOTOCELL CONTROLS | $2,140 | $1,195 | Not Implemented |
MS0148 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,990 | $30,779 | Not Implemented |
MS0023 # 06 Y:1995 | 06 | 1995 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $839 | $120 | Implemented |
MS0023 # 05 Y:1995 | 05 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $577 | $690 | Not Implemented |
MS0023 # 04 Y:1995 | 04 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $918 | $2,400 | Not Implemented |
MS0023 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,350 | $43,100 | Not Implemented |
MS0023 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $606 | $2,134 | Not Implemented |
MS0023 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $7,796 | $4,500 | Not Implemented |