Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,141
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0803 # 09 Y:2009 | 09 | 2009 | KEEP BOILER TUBES CLEAN | $4,480 | $1,000 | Implemented |
UD0803 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,845 | $4,930 | Not Implemented |
UD0803 # 11 Y:2009 | 11 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,432 | $0 | Not Implemented |
UD0803 # 12 Y:2009 | 12 | 2009 | INSTALL OCCUPANCY SENSORS | $1,959 | $1,300 | Not Implemented |
UD0803 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,499 | $1,479 | Not Implemented |
UD0803 # 14 Y:2009 | 14 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $1,120 | $0 | Not Implemented |
UD0803 # 15 Y:2009 | 15 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $663 | $1,125 | Not Implemented |
UD0803 # 16 Y:2009 | 16 | 2009 | DISCONNECT BALLASTS | $428 | $0 | Implemented |
LE0289 # 01 Y:2009 | 01 | 2009 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,778 | $20,000 | Implemented |
LE0289 # 02 Y:2009 | 02 | 2009 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $12,698 | $2,600 | Not Implemented |
LE0289 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,495 | $11,500 | Not Implemented |
LE0289 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,121 | $304 | Implemented |
LE0289 # 05 Y:2009 | 05 | 2009 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,908 | $12,000 | Not Implemented |
LE0289 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,888 | $2,824 | Implemented |
LE0289 # 07 Y:2009 | 07 | 2009 | USE SOLAR HEAT TO HEAT WATER | $1,380 | $3,640 | Not Implemented |
LE0289 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,474 | $16,830 | Not Implemented |
LE0289 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,333 | $6,137 | Not Implemented |
LE0289 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,734 | $18,122 | Not Implemented |
UM0350 # 01 Y:2009 | 01 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $14,346 | $12,800 | Not Implemented |
UM0350 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,487 | $13,000 | Implemented |
UM0350 # 03 Y:2009 | 03 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,300 | $1,500 | Not Implemented |
UM0350 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,744 | $30,000 | Implemented |
UM0350 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,990 | $100 | Not Implemented |
UM0350 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,186 | $10,960 | Not Implemented |
UM0350 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $846 | $474 | Not Implemented |