Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,001
matching recommendationsSIC | 284 | Soap, Cleaners, And Toilet Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0021 # 05 Y:1991 | 05 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $90,586 | $400,000 | Implemented |
AS0021 # 06 Y:1991 | 06 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $17,386 | $18,000 | Implemented |
AS0021 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,885 | $1,000 | Implemented |
AS0021 # 08 Y:1991 | 08 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,180 | $1,760 | Implemented |
AS0021 # 09 Y:1991 | 09 | 1991 | IMPROVE LUBRICATION PRACTICES | $7,796 | $0 | Implemented |
AS0021 # 10 Y:1991 | 10 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,246 | $18,000 | Implemented |
AS0021 # 11 Y:1991 | 11 | 1991 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $101,612 | $1,050,000 | Implemented |
RU0096 # 01 Y:1990 | 01 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,050 | $2,500 | Not Implemented |
RU0096 # 02 Y:1990 | 02 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $805 | $0 | Implemented |
RU0096 # 03 Y:1990 | 03 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,071 | $0 | Not Implemented |
RU0096 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $299 | $64 | Not Implemented |
RU0096 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $888 | $0 | Implemented |
RU0096 # 06 Y:1990 | 06 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $73 | $94 | Not Implemented |
RU0096 # 07 Y:1990 | 07 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,213 | $70 | Implemented |
RU0096 # 08 Y:1990 | 08 | 1990 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,145 | $373 | Not Implemented |
RU0096 # 09 Y:1990 | 09 | 1990 | USE MINIMUM STEAM OPERATING PRESSURE | $4,150 | $0 | Not Implemented |
TN0400 # 01 Y:1990 | 01 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $12,739 | $4,900 | Not Implemented |
TN0400 # 02 Y:1990 | 02 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $7,297 | $13,360 | Not Implemented |
TN0400 # 03 Y:1990 | 03 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $8,711 | $23,808 | Not Implemented |
TN0400 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $1,755 | $6,350 | Implemented |
TN0400 # 05 Y:1990 | 05 | 1990 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,383 | $0 | Implemented |
TN0400 # 06 Y:1990 | 06 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $103 | $180 | Not Implemented |
TN0400 # 07 Y:1990 | 07 | 1990 | INSULATE BARE EQUIPMENT | $280 | $361 | Not Implemented |
MA0170 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $922 | $575 | Not Implemented |
MA0170 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $614 | $60 | Not Implemented |