Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0669 # 01 Y:2013 | 01 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,590 | $15,280 | Implemented |
CO0669 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $4,190 | $4,840 | Not Implemented |
CO0669 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,650 | $390 | Implemented |
OK0855 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,499 | $9,900 | Not Implemented |
OK0855 # 02 Y:2013 | 02 | 2013 | INSTALL SET-BACK TIMERS | $4,654 | $1,287 | Implemented |
OK0855 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,588 | $9,900 | Not Implemented |
OK0855 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $8,807 | $2,070 | Implemented |
OK0855 # 05 Y:2013 | 05 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,342 | $18,900 | Not Implemented |
OK0855 # 06 Y:2013 | 06 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $3,427 | $15,550 | Implemented |
OK0855 # 07 Y:2013 | 07 | 2013 | INSTALL SET-BACK TIMERS | $386 | $1,600 | Not Implemented |
OK0855 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,693 | $20,825 | Implemented |
OK0855 # 09 Y:2013 | 09 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,095 | $69,580 | Implemented |
OK0855 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,628 | $22,407 | Implemented |
OK0855 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,455 | $8,640 | Not Implemented |
OK0855 # 12 Y:2013 | 12 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,606 | $3,000 | Implemented |
OK0855 # 13 Y:2013 | 13 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,337 | $2,676 | Not Implemented |
OK0855 # 14 Y:2013 | 14 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,571 | $3,850 | Not Implemented |
OK0855 # 15 Y:2013 | 15 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,950 | $1,220 | Not Implemented |
OK0855 # 16 Y:2013 | 16 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,059 | $54,000 | Not Implemented |
OK0855 # 17 Y:2013 | 17 | 2013 | INSULATE BARE EQUIPMENT | $7,673 | $1,199 | Not Implemented |
OK0855 # 18 Y:2013 | 18 | 2013 | INSULATE BARE EQUIPMENT | $258 | $960 | Not Implemented |
OK0855 # 19 Y:2013 | 19 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,292 | $6,796 | Not Implemented |
OK0855 # 20 Y:2013 | 20 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,823 | $3,063 | Not Implemented |
OK0855 # 21 Y:2013 | 21 | 2013 | OPTIMIZE PLANT POWER FACTOR | $17,798 | $13,508 | Implemented |
TT0113 # 01 Y:2013 | 01 | 2013 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $12,194 | $0 | Not Implemented |