Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0720 # 05 Y:2016 | 05 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $930 | $1,330 | Not Implemented |
CO0720 # 04 Y:2016 | 04 | 2016 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,510 | $27,600 | Not Implemented |
CO0720 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,190 | $67,155 | Implemented |
CO0720 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,840 | $300 | Implemented |
CO0720 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,640 | $62,670 | Not Implemented |
CO0588 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,244 | $493 | Implemented |
CO0588 # 09 Y:2006 | 09 | 2006 | INSTALL OCCUPANCY SENSORS | $130 | $390 | Not Implemented |
CO0588 # 08 Y:2006 | 08 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,300 | $2,950 | Not Implemented |
CO0588 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,600 | $2,970 | Implemented |
CO0588 # 06 Y:2006 | 06 | 2006 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,680 | $1,310 | Implemented |
CO0588 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,290 | $57,670 | Implemented |
CO0588 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $200 | $510 | Implemented |
CO0588 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,500 | $50 | Implemented |
CO0588 # 01 Y:2006 | 01 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,610 | $9,470 | Implemented |
CO0053 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $1,025 | $1,200 | Implemented |
CO0053 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,306 | $842 | Implemented |
CO0053 # 09 Y:1986 | 09 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,286 | $50,000 | Implemented |
CO0053 # 08 Y:1986 | 08 | 1986 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,332 | $4,000 | Not Implemented |
CO0053 # 07 Y:1986 | 07 | 1986 | IMPROVE LUBRICATION PRACTICES | $1,616 | $0 | Implemented |
CO0053 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,436 | $1,100 | Not Implemented |
CO0053 # 05 Y:1986 | 05 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,464 | $4,000 | Not Implemented |
CO0053 # 04 Y:1986 | 04 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,947 | $3,700 | Not Implemented |
CO0053 # 03 Y:1986 | 03 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,522 | $280 | Implemented |
CO0053 # 02 Y:1986 | 02 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $673 | $1,100 | Not Implemented |