Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
301
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0115 # 08 Y:1991 | 08 | 1991 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $5,372 | $875 | Implemented |
RU0029 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $834 | $322 | Implemented |
RU0029 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $654 | $202 | Implemented |
RU0029 # 03 Y:1988 | 03 | 1988 | INSTALL SET-BACK TIMERS | $1,898 | $0 | Not Implemented |
RU0029 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,940 | $0 | Implemented |
RU0029 # 05 Y:1988 | 05 | 1988 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $933 | $0 | Implemented |
RU0027 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,617 | $682 | Implemented |
RU0027 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $409 | $202 | Implemented |
RU0027 # 03 Y:1988 | 03 | 1988 | INSTALL SET-BACK TIMERS | $8,562 | $0 | Implemented |
RU0027 # 04 Y:1988 | 04 | 1988 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,810 | $3,104 | Not Implemented |
RU0027 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,692 | $1,800 | Not Implemented |
RU0027 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,612 | $500 | Implemented |
RU0012 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $302 | $600 | Implemented |
RU0012 # 02 Y:1987 | 02 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,052 | $3,750 | Implemented |
RU0012 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $568 | $0 | Not Implemented |
RU0012 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $213 | $82 | Implemented |
RU0012 # 05 Y:1987 | 05 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $5,664 | $2,800 | Implemented |
RU0012 # 06 Y:1987 | 06 | 1987 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $695 | $710 | Implemented |
ST0070 # 01 Y:1986 | 01 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $2,865 | $105 | Implemented |
ST0070 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $904 | $1,600 | Implemented |
ST0070 # 03 Y:1986 | 03 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $509 | $0 | Implemented |
ST0070 # 04 Y:1986 | 04 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $463 | $1,500 | Implemented |
ST0070 # 05 Y:1986 | 05 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,395 | $7,000 | Implemented |
ST0070 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,882 | $10,665 | Implemented |
ST0070 # 07 Y:1986 | 07 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $31,161 | $0 | Implemented |