Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,727
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0105 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $486 | $293 | Implemented |
WV0105 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $878 | $120 | Implemented |
WV0105 # 05 Y:1996 | 05 | 1996 | INSULATE BARE EQUIPMENT | $1,469 | $214 | Not Implemented |
WV0105 # 06 Y:1996 | 06 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,689 | $7,100 | Not Implemented |
WV0105 # 07 Y:1996 | 07 | 1996 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $7,620 | $5,400 | Not Implemented |
WV0105 # 08 Y:1996 | 08 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,370 | $500 | Implemented |
SF0102 # 01 Y:1996 | 01 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,138 | $0 | Not Implemented |
SF0102 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,562 | $5,950 | Not Implemented |
SF0102 # 03 Y:1996 | 03 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $980 | $1,804 | Not Implemented |
SF0102 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $261 | $50 | Implemented |
SF0102 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $346 | $308 | Implemented |
ME0199 # 01 Y:1996 | 01 | 1996 | INSULATE BARE EQUIPMENT | $2,217 | $4,609 | Implemented |
ME0199 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,598 | $6,309 | Implemented |
ME0199 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $721 | $1,053 | Implemented |
ME0199 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $699 | $100 | Implemented |
ME0199 # 05 Y:1996 | 05 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $475 | $0 | Implemented |
ME0199 # 06 Y:1996 | 06 | 1996 | USE MORE EFFICIENT ADHESIVE APPLICATORS | $36,387 | $43,500 | Implemented |
ME0199 # 07 Y:1996 | 07 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $2,978 | $5,380 | Implemented |
ME0199 # 08 Y:1996 | 08 | 1996 | MINIMIZE WATER USAGE | $492 | $218 | Implemented |
GT0596 # 01 Y:1996 | 01 | 1996 | COMBINE UTILITY METERS | $3,080 | $5,000 | Not Implemented |
GT0596 # 02 Y:1996 | 02 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $19,400 | $0 | Implemented |
GT0596 # 03 Y:1996 | 03 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,000 | $41,250 | Implemented |
GT0596 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,410 | $200 | Implemented |
GT0596 # 05 Y:1996 | 05 | 1996 | USE LESS WASTEFUL PACKAGING | $58,140 | $38,250 | Not Implemented |
GT0596 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,576 | $3,850 | Not Implemented |