Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
327
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0295 # 05 Y:2016 | 05 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,874 | $40 | Not Implemented |
MI0295 # 06 Y:2016 | 06 | 2016 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $7,334 | $4,411 | Not Implemented |
MI0295 # 07 Y:2016 | 07 | 2016 | PAY UTILITY BILLS ON TIME | $4,723 | $0 | Not Implemented |
MI0295 # 08 Y:2016 | 08 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,957 | $1,660 | Not Implemented |
MI0295 # 09 Y:2016 | 09 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,084 | $320 | Not Implemented |
MI0295 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $1,284 | $683 | Not Implemented |
MI0295 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $448 | $640 | Not Implemented |
MI0242 # 01 Y:2013 | 01 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $21,241 | $34,743 | Implemented |
MI0242 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,999 | $3,900 | Implemented |
MI0242 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $17,438 | $17,835 | Implemented |
MI0242 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,166 | $1,660 | Implemented |
MI0242 # 05 Y:2013 | 05 | 2013 | INSTALL SKYLIGHTS | $6,558 | $4,950 | Implemented |
MI0242 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,239 | $8,000 | Implemented |
MI0242 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,147 | $4,000 | Not Implemented |
MI0242 # 08 Y:2013 | 08 | 2013 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,703 | $793 | Implemented |
MI0242 # 09 Y:2013 | 09 | 2013 | INSTALL OCCUPANCY SENSORS | $1,486 | $137 | Not Implemented |
MI0242 # 10 Y:2013 | 10 | 2013 | INSTALL OCCUPANCY SENSORS | $1,303 | $80 | Not Implemented |
MI0229 # 01 Y:2012 | 01 | 2012 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $69,199 | $111,000 | Implemented |
MI0229 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,024 | $168,378 | Not Implemented |
MI0229 # 03 Y:2012 | 03 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $26,164 | $22,464 | Implemented |
MI0229 # 04 Y:2012 | 04 | 2012 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $21,533 | $46,296 | Not Implemented |
MI0229 # 05 Y:2012 | 05 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,948 | $7,160 | Not Implemented |
MI0229 # 06 Y:2012 | 06 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,915 | $80 | Implemented |
MI0229 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,865 | $1,660 | Implemented |
MI0229 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,849 | $80 | Implemented |