Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,698
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0185 # 03 Y:1983 | 03 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,000 | $2,000 | Not Implemented |
TN0187 # 01 Y:1983 | 01 | 1983 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $-14,400 | $10,000 | Not Implemented |
TN0187 # 02 Y:1983 | 02 | 1983 | ADJUST VENTS TO MINIMIZE ENERGY USE | $1,540 | $0 | Not Implemented |
TN0187 # 03 Y:1983 | 03 | 1983 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $265 | $0 | Not Implemented |
TN0189 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $530 | $4,000 | Not Implemented |
TN0189 # 02 Y:1983 | 02 | 1983 | UPGRADE OBSOLETE EQUIPMENT | $540 | $60 | Not Implemented |
OK0106 # 01 Y:1983 | 01 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $35,511 | $1,133 | Implemented |
OK0106 # 02 Y:1983 | 02 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $99 | $148 | Not Implemented |
OK0106 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $109 | $73 | Implemented |
OK0106 # 04 Y:1983 | 04 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,552 | $3,810 | Implemented |
OK0106 # 09 Y:1983 | 09 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,084 | $2,528 | Implemented |
OK0106 # 10 Y:1983 | 10 | 1983 | USE UTILITY CONTROLLED POWER MANAGEMENT | $6,953 | $0 | Implemented |
OK0106 # 11 Y:1983 | 11 | 1983 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $68 | $0 | Implemented |
OK0106 # 12 Y:1983 | 12 | 1983 | USE OPTIMUM THICKNESS INSULATION | $28,546 | $6,480 | Implemented |
KU0088 # 01 Y:1983 | 01 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $896 | $450 | Not Implemented |
KU0088 # 02 Y:1983 | 02 | 1983 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $551 | $70 | Implemented |
KU0088 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $309 | $312 | Not Implemented |
KU0088 # 04 Y:1983 | 04 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $111 | $300 | Not Implemented |
KU0088 # 05 Y:1983 | 05 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $63 | $60 | Not Implemented |
OK0099 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $125 | $143 | Not Implemented |
OK0099 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $215 | $600 | Not Implemented |
OK0099 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,530 | $3,400 | Not Implemented |
OK0099 # 04 Y:1983 | 04 | 1983 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $145 | $498 | Not Implemented |
OK0099 # 05 Y:1983 | 05 | 1983 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $393 | $52 | Not Implemented |
OK0099 # 06 Y:1983 | 06 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $548 | $25 | Not Implemented |