Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0136 # 08 Y:1992 | 08 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,333 | $0 | Not Implemented |
WI0136 # 09 Y:1992 | 09 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $931 | $1,500 | Not Implemented |
WI0136 # 10 Y:1992 | 10 | 1992 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $475 | $450 | Not Implemented |
WI0094 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,067 | $3,222 | Not Implemented |
WI0094 # 02 Y:1990 | 02 | 1990 | INSTALL STORM WINDOWS AND DOORS | $3,800 | $8,566 | Not Implemented |
WI0094 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $2,284 | $1,000 | Implemented |
WI0094 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $975 | $500 | Implemented |
WI0094 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $505 | $0 | Implemented |
WI0094 # 06 Y:1990 | 06 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $489 | $1,500 | Not Implemented |
WI0094 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $219 | $800 | Implemented |
WI0094 # 08 Y:1990 | 08 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $508 | $700 | Not Implemented |
WI0084 # 01 Y:1990 | 01 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,340 | $0 | Not Implemented |
WI0084 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,910 | $2,000 | Implemented |
WI0084 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $705 | $1,328 | Implemented |
WI0084 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $930 | $2,000 | Implemented |
WI0084 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $730 | $600 | Not Implemented |
WI0084 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $478 | $250 | Implemented |
WI0014 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $3,768 | $0 | Not Implemented |
WI0014 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,879 | $0 | Implemented |
WI0014 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,792 | $285 | Implemented |
WI0014 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,818 | $950 | Not Implemented |
WI0014 # 06 Y:1987 | 06 | 1987 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $431 | $700 | Implemented |