Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,344

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ST0080 # 01 Y:1986 01 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $18,901 $59,000 Not Implemented
ST0080 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $9,482 $7,000 Implemented
ST0080 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,370 $0 Implemented
ST0080 # 04 Y:1986 04 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $531 $1,333 Implemented
ST0080 # 05 Y:1986 05 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,206 $558 Implemented
ST0080 # 06 Y:1986 06 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,264 $2,016 Implemented
ST0080 # 07 Y:1986 07 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,682 $6,000 Not Implemented
LT0066 # 01 Y:1986 01 1986 INSTALL SET-BACK TIMERS $602 $210 Not Implemented
LT0066 # 02 Y:1986 02 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,230 $12,000 Implemented
LT0066 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $837 $334 Not Implemented
LT0066 # 04 Y:1986 04 1986 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $84 $8 Not Implemented
KU0209 # 01 Y:1986 01 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $37,717 $30,000 Not Implemented
KU0209 # 02 Y:1986 02 1986 IMPROVE LUBRICATION PRACTICES $23,084 $20,000 Not Implemented
KU0209 # 03 Y:1986 03 1986 INSTALL AUTOMATIC STACK DAMPER $19,573 $13,500 Not Implemented
KU0209 # 04 Y:1986 04 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $25,756 $5,000 Not Implemented
KU0209 # 05 Y:1986 05 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $11,981 $20,000 Implemented
KU0209 # 06 Y:1986 06 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,092 $0 Not Implemented
KU0209 # 07 Y:1986 07 1986 INSTALL TIMERS AND/OR THERMOSTATS $3,611 $945 Implemented
KU0209 # 08 Y:1986 08 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,187 $5,000 Implemented
KU0209 # 09 Y:1986 09 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,209 $3,372 Implemented
KU0209 # 10 Y:1986 10 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,842 $8,000 Not Implemented
KU0209 # 11 Y:1986 11 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,687 $7,500 Not Implemented
KU0209 # 12 Y:1986 12 1986 SHUT OFF PILOTS IN STANDBY EQUIPMENT $809 $0 Implemented
KU0209 # 13 Y:1986 13 1986 KEEP BOILER TUBES CLEAN $796 $1,600 Implemented
KU0209 # 14 Y:1986 14 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $736 $50 Implemented