Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,069

matching recommendations
Reset
SIC 332 Iron And Steel Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0326 # 01 Y:2007 01 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $26,782 $1,000 Not Implemented
UM0326 # 02 Y:2007 02 2007 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $8,825 $13,130 Implemented
UM0326 # 03 Y:2007 03 2007 COVER OPEN TANKS $4,631 $220 Implemented
UM0326 # 04 Y:2007 04 2007 RECOVER WASTE HEAT FROM EQUIPMENT $3,591 $500 Implemented
UM0326 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,234 $675 Implemented
UM0326 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,191 $1,860 Implemented
UM0326 # 07 Y:2007 07 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,476 $2,200 Implemented
UM0326 # 08 Y:2007 08 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,092 $204 Implemented
UM0326 # 09 Y:2007 09 2007 INSTALL OCCUPANCY SENSORS $253 $600 Implemented
SD0397 # 01 Y:2007 01 2007 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $51,686 $51,240 Not Implemented
SD0397 # 02 Y:2007 02 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $52,328 $44,175 Not Implemented
SD0397 # 03 Y:2007 03 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,149 $18,100 Not Implemented
SD0397 # 04 Y:2007 04 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,700 $23,250 Not Implemented
SD0397 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,897 $420 Implemented
SD0397 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,198 $17,214 Implemented
SD0397 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,697 $71,224 Implemented
SD0397 # 08 Y:2007 08 2007 INSTALL SKYLIGHTS $4,924 $13,330 Not Implemented
SD0397 # 09 Y:2007 09 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,243 $3,825 Not Implemented
UA0004 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,724 $34,990 Not Implemented
UA0004 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,674 $974 Not Implemented
UA0004 # 03 Y:2007 03 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,587 $0 Implemented
UA0004 # 04 Y:2007 04 2007 INSTALL TIMERS AND/OR THERMOSTATS $435 $1,534 Not Implemented
UA0004 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,488 $1,400 Not Implemented
UA0004 # 06 Y:2007 06 2007 SHUT OFF PILOTS IN STANDBY EQUIPMENT $2,169 $230 Implemented
UA0004 # 07 Y:2007 07 2007 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $5,479 $400 Not Implemented