Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TS0015 # 01 Y:1985 | 01 | 1985 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $7,193 | $7,000 | Implemented |
TS0015 # 02 Y:1985 | 02 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $951 | $575 | Implemented |
TS0015 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $433 | $150 | Implemented |
TS0015 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $376 | $0 | Implemented |
TS0015 # 05 Y:1985 | 05 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,190 | $2,100 | Implemented |
LT0014 # 01 Y:1984 | 01 | 1984 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $75,700 | $1,000 | Implemented |
LT0014 # 02 Y:1984 | 02 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,320 | $332 | Implemented |
LT0014 # 03 Y:1984 | 03 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $674 | $1,525 | Implemented |
LT0014 # 04 Y:1984 | 04 | 1984 | OPTIMIZE PLANT POWER FACTOR | $25,600 | $15,000 | Implemented |
LT0014 # 05 Y:1984 | 05 | 1984 | OPTIMIZE PLANT POWER FACTOR | $8,800 | $840 | Implemented |
UD0143 # 01 Y:1984 | 01 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,182 | $0 | Implemented |
UD0143 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $2,369 | $2,500 | Implemented |
UD0143 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,542 | $387 | Implemented |
UD0143 # 04 Y:1984 | 04 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,512 | $7,000 | Not Implemented |
OK0139 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $90 | $325 | Not Implemented |
OK0139 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $519 | $115 | Not Implemented |
OK0139 # 03 Y:1984 | 03 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $429 | $130 | Not Implemented |
OK0139 # 04 Y:1984 | 04 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $626 | $135 | Not Implemented |
OK0139 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $222 | $0 | Not Implemented |
OK0139 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52 | $180 | Not Implemented |
UD0119 # 01 Y:1984 | 01 | 1984 | REVISE SMOKE CLEANUP FROM OPERATIONS | $5,989 | $1,000 | Implemented |
UD0119 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,135 | $700 | Implemented |
UD0119 # 03 Y:1984 | 03 | 1984 | REDESIGN PROCESS | $683 | $2,000 | Implemented |
UD0119 # 04 Y:1984 | 04 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $162 | $700 | Implemented |
OK0111 # 01 Y:1983 | 01 | 1983 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $113 | $418 | Not Implemented |