Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,208

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0594 # 03 Y:2017 03 2017 UPGRADE CONTROLS ON COMPRESSORS $5,016 $8,200 Implemented
NC0594 # 04 Y:2017 04 2017 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,502 $1,000 Implemented
NC0594 # 05 Y:2017 05 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $979 $100 Implemented
NC0594 # 06 Y:2017 06 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,732 $50 Implemented
NC0594 # 07 Y:2017 07 2017 RECOVER WASTE HEAT FROM EQUIPMENT $2,917 $3,500 Not Implemented
NC0594 # 08 Y:2017 08 2017 RECOVER WASTE HEAT FROM EQUIPMENT $10,457 $20,000 Not Implemented
NC0594 # 09 Y:2017 09 2017 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $261 $200 Not Implemented
UK1702 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $14,192 $23,388 Not Implemented
UK1702 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,889 $28,344 Not Implemented
UK1702 # 03 Y:2017 03 2017 INSTALL OCCUPANCY SENSORS $1,545 $1,527 Not Implemented
UK1702 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $302 $110 Not Implemented
UK1702 # 05 Y:2017 05 2017 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $8,763 $5,000 Not Implemented
UK1702 # 06 Y:2017 06 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,044 $0 Not Implemented
UK1702 # 07 Y:2017 07 2017 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,290 $250 Not Implemented
UK1702 # 08 Y:2017 08 2017 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,198 $9,640 Not Implemented
UK1702 # 09 Y:2017 09 2017 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,253 $183 Not Implemented
UK1702 # 10 Y:2017 10 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,626 $1,253 Not Implemented
UK1702 # 11 Y:2017 11 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,053 $2,000 Not Implemented
UK1702 # 12 Y:2017 12 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,272 $0 Not Implemented
UK1702 # 13 Y:2017 13 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,078 $0 Not Implemented
UK1702 # 14 Y:2017 14 2017 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $1,046 $0 Not Implemented
UK1702 # 15 Y:2017 15 2017 METER WASTE WATER $10,854 $1,642 Not Implemented
UK1702 # 16 Y:2017 16 2017 CLEAN CONDENSER TUBES $1,879 $300 Not Implemented
UK1702 # 17 Y:2017 17 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,048 $0 Not Implemented
OK0967 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,854 $3,960 Not Implemented