Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

415

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0240 # 05 Y:1992 05 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,896 $0 Implemented
MA0240 # 06 Y:1992 06 1992 INSTALL SET-BACK TIMERS $1,400 $400 Implemented
MA0240 # 07 Y:1992 07 1992 REPAIR OR REPLACE STEAM TRAPS $1,348 $240 Implemented
MA0240 # 08 Y:1992 08 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,022 $2,200 Implemented
MA0186 # 01 Y:1990 01 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,664 $5,000 Implemented
MA0186 # 02 Y:1990 02 1990 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,372 $5,957 Not Implemented
MA0186 # 03 Y:1990 03 1990 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,848 $500 Implemented
MA0186 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,333 $9,634 Implemented
MA0186 # 05 Y:1990 05 1990 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,130 $1,195 Implemented
MA0186 # 06 Y:1990 06 1990 COVER OPEN TANKS $1,262 $229 Implemented
MA0182 # 01 Y:1990 01 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $5,921 $116,600 Implemented
MA0182 # 02 Y:1990 02 1990 INSTALL SET-BACK TIMERS $368 $440 Implemented
MA0182 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $678 $336 Implemented
MA0182 # 04 Y:1990 04 1990 INSULATE BARE EQUIPMENT $644 $1,540 Not Implemented
MA0182 # 05 Y:1990 05 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $471 $675 Implemented
MA0182 # 06 Y:1990 06 1990 REDUCE VENTILATION AIR $2,509 $500 Not Implemented
MA0175 # 01 Y:1990 01 1990 INSTALL SET-BACK TIMERS $293 $129 Not Implemented
MA0175 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $385 $0 Implemented
MA0175 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,043 $234 Not Implemented
MA0175 # 04 Y:1990 04 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,216 $5,256 Implemented
MA0175 # 05 Y:1990 05 1990 OPTIMIZE PLANT POWER FACTOR $1,528 $2,710 Implemented
MA0160 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $364 $535 Not Implemented
MA0160 # 02 Y:1989 02 1989 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $434 $0 Implemented
MA0160 # 03 Y:1989 03 1989 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,675 $1,000 Not Implemented
MA0160 # 04 Y:1989 04 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,708 $1,000 Implemented