Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
415
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0240 # 05 Y:1992 | 05 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,896 | $0 | Implemented |
MA0240 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $1,400 | $400 | Implemented |
MA0240 # 07 Y:1992 | 07 | 1992 | REPAIR OR REPLACE STEAM TRAPS | $1,348 | $240 | Implemented |
MA0240 # 08 Y:1992 | 08 | 1992 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,022 | $2,200 | Implemented |
MA0186 # 01 Y:1990 | 01 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,664 | $5,000 | Implemented |
MA0186 # 02 Y:1990 | 02 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,372 | $5,957 | Not Implemented |
MA0186 # 03 Y:1990 | 03 | 1990 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,848 | $500 | Implemented |
MA0186 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,333 | $9,634 | Implemented |
MA0186 # 05 Y:1990 | 05 | 1990 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,130 | $1,195 | Implemented |
MA0186 # 06 Y:1990 | 06 | 1990 | COVER OPEN TANKS | $1,262 | $229 | Implemented |
MA0182 # 01 Y:1990 | 01 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,921 | $116,600 | Implemented |
MA0182 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $368 | $440 | Implemented |
MA0182 # 03 Y:1990 | 03 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $678 | $336 | Implemented |
MA0182 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $644 | $1,540 | Not Implemented |
MA0182 # 05 Y:1990 | 05 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $471 | $675 | Implemented |
MA0182 # 06 Y:1990 | 06 | 1990 | REDUCE VENTILATION AIR | $2,509 | $500 | Not Implemented |
MA0175 # 01 Y:1990 | 01 | 1990 | INSTALL SET-BACK TIMERS | $293 | $129 | Not Implemented |
MA0175 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $385 | $0 | Implemented |
MA0175 # 03 Y:1990 | 03 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,043 | $234 | Not Implemented |
MA0175 # 04 Y:1990 | 04 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,216 | $5,256 | Implemented |
MA0175 # 05 Y:1990 | 05 | 1990 | OPTIMIZE PLANT POWER FACTOR | $1,528 | $2,710 | Implemented |
MA0160 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $364 | $535 | Not Implemented |
MA0160 # 02 Y:1989 | 02 | 1989 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $434 | $0 | Implemented |
MA0160 # 03 Y:1989 | 03 | 1989 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,675 | $1,000 | Not Implemented |
MA0160 # 04 Y:1989 | 04 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,708 | $1,000 | Implemented |