Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

44

matching recommendations
Reset
SIC 342 Cutlery, Handtools, And Hardware
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0119 # 05 Y:1988 05 1988 INSTALL TIMERS AND/OR THERMOSTATS $2,794 $4,000 Not Implemented
CO0119 # 04 Y:1988 04 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,270 $10,400 Not Implemented
CO0119 # 03 Y:1988 03 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $889 $0 Implemented
CO0119 # 01 Y:1988 01 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $711 $500 Implemented
CO0119 # 10 Y:1988 10 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $487 $250 Implemented
CO0042 # 14 Y:1985 14 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,475 $1,459 Implemented
CO0042 # 13 Y:1985 13 1985 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,837 $5,000 Not Implemented
CO0042 # 12 Y:1985 12 1985 INSTALL STORM WINDOWS AND DOORS $7,925 $4,000 Not Implemented
CO0042 # 11 Y:1985 11 1985 INSTALL TIMERS AND/OR THERMOSTATS $18,823 $500 Implemented
CO0042 # 10 Y:1985 10 1985 COVER OPEN TANKS $1,052 $234 Not Implemented
CO0042 # 09 Y:1985 09 1985 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $1,421 $5,500 Not Implemented
CO0042 # 08 Y:1985 08 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,256 $2,000 Not Implemented
CO0042 # 07 Y:1985 07 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,926 $200 Implemented
CO0042 # 06 Y:1985 06 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $69 $100 Not Implemented
CO0042 # 05 Y:1985 05 1985 RECOVER WASTE HEAT FROM EQUIPMENT $283 $200 Implemented
CO0042 # 04 Y:1985 04 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,923 $600 Not Implemented
CO0042 # 03 Y:1985 03 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $91 $100 Not Implemented
CO0042 # 02 Y:1985 02 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $6,858 $450 Not Implemented
CO0042 # 01 Y:1985 01 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,853 $645 Implemented