Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,203

matching recommendations
Reset
SIC 342 Cutlery, Handtools, And Hardware
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0118 # 02 Y:1995 02 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,560 $20 Implemented
SD0118 # 03 Y:1995 03 1995 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $202 $300 Implemented
SD0118 # 04 Y:1995 04 1995 USE PHOTOCELL CONTROLS $774 $140 Implemented
SD0118 # 05 Y:1995 05 1995 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $578 $100 Implemented
SD0118 # 06 Y:1995 06 1995 INSTALL TIMERS AND/OR THERMOSTATS $6,794 $1,430 Implemented
SD0118 # 07 Y:1995 07 1995 BURN WOOD BY-PRODUCTS FOR HEAT $9,000 $5,000 Not Implemented
SD0118 # 08 Y:1995 08 1995 IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM $3,902 $500 Implemented
WV0059 # 01 Y:1995 01 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,855 $3,000 Not Implemented
WV0059 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,147 $4,000 Implemented
WV0059 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $539 $280 Implemented
WV0059 # 04 Y:1995 04 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $208 $366 Not Implemented
IA0108 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,025 $240 Not Implemented
IA0108 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,336 $860 Implemented
IA0108 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $442 $770 Implemented
IA0108 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $622 $142 Not Implemented
IA0108 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $427 $1,142 Implemented
IA0108 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $513 $200 Implemented
IA0108 # 07 Y:1995 07 1995 REPLACE HEXAVALENT CHROMIUM SOLUTIONS WITH TRIVALENT SOLUTIONS $3,023 $0 Not Implemented
IA0108 # 08 Y:1995 08 1995 USE SQUEEGEES, MOPS, AND VACUUMS FOR FLOOR CLEANING $589 $400 Implemented
ND0195 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $31,885 $23,230 Implemented
ND0195 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $19,025 $750 Implemented
ND0195 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,596 $242 Implemented
ND0195 # 04 Y:1994 04 1994 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $8,963 $12,476 Implemented
ND0195 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $8,212 $900 Not Implemented
ND0195 # 06 Y:1994 06 1994 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $6,250 $1,500 Implemented