Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,203
matching recommendationsSIC | 342 | Cutlery, Handtools, And Hardware |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0043 # 07 Y:1985 | 07 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $662 | $0 | Implemented |
CO0042 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,853 | $645 | Implemented |
CO0042 # 02 Y:1985 | 02 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,858 | $450 | Not Implemented |
CO0042 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $91 | $100 | Not Implemented |
CO0042 # 04 Y:1985 | 04 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,923 | $600 | Not Implemented |
CO0042 # 05 Y:1985 | 05 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $283 | $200 | Implemented |
CO0042 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $69 | $100 | Not Implemented |
CO0042 # 07 Y:1985 | 07 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,926 | $200 | Implemented |
CO0042 # 08 Y:1985 | 08 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,256 | $2,000 | Not Implemented |
CO0042 # 09 Y:1985 | 09 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $1,421 | $5,500 | Not Implemented |
CO0042 # 10 Y:1985 | 10 | 1985 | COVER OPEN TANKS | $1,052 | $234 | Not Implemented |
CO0042 # 11 Y:1985 | 11 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $18,823 | $500 | Implemented |
CO0042 # 12 Y:1985 | 12 | 1985 | INSTALL STORM WINDOWS AND DOORS | $7,925 | $4,000 | Not Implemented |
CO0042 # 13 Y:1985 | 13 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,837 | $5,000 | Not Implemented |
CO0042 # 14 Y:1985 | 14 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,475 | $1,459 | Implemented |
AT0005 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $1,183 | Implemented |
AT0005 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,390 | $300 | Implemented |
AT0005 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $291 | $400 | Implemented |
AT0005 # 04 Y:1985 | 04 | 1985 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,384 | $226 | Implemented |
AT0005 # 05 Y:1985 | 05 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $346 | $0 | Not Implemented |
AT0005 # 06 Y:1985 | 06 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $24,347 | $1,200 | Implemented |
OK0153 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $89 | $75 | Implemented |
OK0153 # 02 Y:1985 | 02 | 1985 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $580 | $300 | Not Implemented |
OK0153 # 03 Y:1985 | 03 | 1985 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $104 | $259 | Not Implemented |
OK0153 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $282 | $130 | Not Implemented |