Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

859

matching recommendations
Reset
SIC 3442 Metal Doors, Sash, And Trim
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0110 # 01 Y:1991 01 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $527 $0 Implemented
RU0110 # 02 Y:1991 02 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,910 $1,133 Implemented
RU0110 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,407 $0 Implemented
RU0110 # 04 Y:1991 04 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,640 $5,700 Implemented
RU0110 # 05 Y:1991 05 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $693 $0 Implemented
RU0110 # 06 Y:1991 06 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,009 $500 Implemented
RU0110 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $542 $162 Implemented
WI0110 # 01 Y:1991 01 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,416 $3,500 Implemented
WI0110 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,123 $546 Implemented
WI0110 # 03 Y:1991 03 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $282 $500 Implemented
WI0110 # 04 Y:1991 04 1991 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,840 $9,000 Implemented
WI0110 # 05 Y:1991 05 1991 INSTALL STORM WINDOWS AND DOORS $1,141 $6,311 Implemented
WI0110 # 06 Y:1991 06 1991 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,062 $2,214 Implemented
WI0110 # 07 Y:1991 07 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $346 $800 Implemented
GT0426 # 01 Y:1990 01 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,559 $300 Implemented
GT0426 # 02 Y:1990 02 1990 KEEP BOILER TUBES CLEAN $257 $200 Implemented
GT0426 # 03 Y:1990 03 1990 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $1,520 $500 Not Implemented
GT0426 # 04 Y:1990 04 1990 INSTALL TIMERS AND/OR THERMOSTATS $270 $0 Implemented
GT0426 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $328 $133 Implemented
GT0426 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $87 $141 Not Implemented
GT0426 # 07 Y:1990 07 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $419 $358 Implemented
GT0426 # 08 Y:1990 08 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $480 $0 Implemented
GT0426 # 09 Y:1990 09 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,331 $0 Implemented
OK0321 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $39,907 $25,000 Implemented
OK0321 # 02 Y:1990 02 1990 RECOVER WASTE HEAT FROM EQUIPMENT $8,220 $2,876 Implemented