Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,214
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0539 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,360 | $400 | Implemented |
GT0539 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,060 | $5,550 | Implemented |
GT0539 # 04 Y:1994 | 04 | 1994 | ISOLATE HOT OR COLD EQUIPMENT | $21,350 | $34,500 | Not Implemented |
SD0082 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,320 | $2,540 | Implemented |
SD0082 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,666 | $800 | Implemented |
SD0082 # 03 Y:1994 | 03 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $34,607 | $925 | Not Implemented |
SD0082 # 04 Y:1994 | 04 | 1994 | REPAIR AND ELIMINATE STEAM LEAKS | $4,140 | $450 | Implemented |
SD0082 # 05 Y:1994 | 05 | 1994 | CLOSE OFF UNNEEDED STEAM LINES | $3,376 | $2,500 | Not Implemented |
SD0082 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $1,613 | $655 | Implemented |
SD0082 # 07 Y:1994 | 07 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,678 | $570 | Implemented |
SD0082 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,278 | $3,560 | Implemented |
SD0082 # 09 Y:1994 | 09 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,162 | $5,175 | Not Implemented |
SD0082 # 10 Y:1994 | 10 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $57 | $25 | Not Implemented |
SD0082 # 11 Y:1994 | 11 | 1994 | USE PHOTOCELL CONTROLS | $594 | $230 | Not Implemented |
UF0081 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,050 | $298 | Not Implemented |
UF0081 # 02 Y:1994 | 02 | 1994 | INSTALL OCCUPANCY SENSORS | $320 | $384 | Not Implemented |
UF0081 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $432 | $1,818 | Not Implemented |
UF0081 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,041 | $200 | Not Implemented |
UF0081 # 05 Y:1994 | 05 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,794 | $2,780 | Not Implemented |
UF0081 # 06 Y:1994 | 06 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $432 | $1,242 | Not Implemented |
WI0198 # 01 Y:1994 | 01 | 1994 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $10,895 | $20,000 | Not Implemented |
WI0198 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,761 | $8,956 | Implemented |
WI0198 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $290 | $150 | Not Implemented |
WI0198 # 04 Y:1994 | 04 | 1994 | USE PHOTOCELL CONTROLS | $116 | $75 | Not Implemented |
WI0198 # 05 Y:1994 | 05 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,734 | $21,885 | Not Implemented |