Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,512
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0161 # 02 Y:1993 | 02 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,238 | $675 | Not Implemented |
ND0161 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $535 | $661 | Not Implemented |
ND0161 # 04 Y:1993 | 04 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $578 | $1,660 | Not Implemented |
ND0161 # 05 Y:1993 | 05 | 1993 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $527 | $80 | Implemented |
ND0161 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28 | $40 | Not Implemented |
UF0065 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,008 | $743 | Not Implemented |
UF0065 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $835 | $4,141 | Not Implemented |
UF0065 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,219 | $4,702 | Not Implemented |
UF0065 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $200 | $800 | Not Implemented |
UF0065 # 05 Y:1993 | 05 | 1993 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,871 | $5,900 | Not Implemented |
UF0065 # 06 Y:1993 | 06 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,015 | $3,000 | Not Implemented |
AS0079 # 01 Y:1993 | 01 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $629 | $1,000 | Not Implemented |
AS0079 # 02 Y:1993 | 02 | 1993 | USE SYNTHETIC LUBRICANT | $228 | $0 | Not Implemented |
AS0079 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $926 | $400 | Not Implemented |
AS0079 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $157 | $208 | Not Implemented |
AS0079 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $359 | $0 | Not Implemented |
AS0079 # 06 Y:1993 | 06 | 1993 | USE HEAT PUMP FOR SPACE CONDITIONING | $357 | $1,420 | Not Implemented |
AS0079 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,526 | $5,661 | Not Implemented |
AS0079 # 08 Y:1993 | 08 | 1993 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,040 | $3,550 | Not Implemented |
CO0262 # 01 Y:1993 | 01 | 1993 | REDUCE VENTILATION AIR | $6,630 | $250 | Implemented |
CO0262 # 02 Y:1993 | 02 | 1993 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,050 | $250 | Implemented |
CO0262 # 03 Y:1993 | 03 | 1993 | REDUCE VENTILATION AIR | $560 | $30 | Implemented |
CO0262 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,250 | $90 | Implemented |
CO0262 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $640 | $240 | Implemented |
CO0262 # 06 Y:1993 | 06 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $200 | Implemented |