Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0104 # 03 Y:1983 | 03 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $995 | $750 | Implemented |
OK0104 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $139 | $148 | Implemented |
OK0104 # 05 Y:1983 | 05 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $174 | $425 | Implemented |
OK0104 # 06 Y:1983 | 06 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,571 | $65 | Implemented |
GT0166 # 01 Y:1983 | 01 | 1983 | COVER OPEN TANKS | $15,260 | $6,300 | Not Implemented |
GT0166 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,800 | $21,480 | Not Implemented |
GT0166 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,300 | $4,538 | Not Implemented |
GT0166 # 04 Y:1983 | 04 | 1983 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,570 | $200 | Not Implemented |
GT0166 # 05 Y:1983 | 05 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,811 | $500 | Not Implemented |
GT0166 # 06 Y:1983 | 06 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,370 | $127 | Not Implemented |
UD0056 # 01 Y:1982 | 01 | 1982 | INSTALL STORM WINDOWS AND DOORS | $773 | $600 | Not Implemented |
UD0056 # 02 Y:1982 | 02 | 1982 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $232,119 | $517,000 | Not Implemented |
UD0056 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,145 | $517,000 | Not Implemented |
UD0052 # 01 Y:1982 | 01 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,538 | $900 | Not Implemented |
UD0052 # 02 Y:1982 | 02 | 1982 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $182,775 | $87,000 | Not Implemented |
UD0052 # 03 Y:1982 | 03 | 1982 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $27,811 | $0 | Not Implemented |