Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,093
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0336 # 10 Y:1991 | 10 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $366 | $0 | Implemented |
KU0336 # 11 Y:1991 | 11 | 1991 | RECOVER AND REUSE COOLING WATER | $9,720 | $5,340 | Implemented |
MA0207 # 01 Y:1991 | 01 | 1991 | USE RADIANT HEATER FOR SPOT HEATING | $9,335 | $20,000 | Implemented |
MA0207 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $691 | $2,857 | Implemented |
MA0207 # 03 Y:1991 | 03 | 1991 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $5,388 | $2,800 | Implemented |
MA0207 # 04 Y:1991 | 04 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,202 | $0 | Implemented |
MA0207 # 05 Y:1991 | 05 | 1991 | OPTIMIZE PLANT POWER FACTOR | $2,718 | $4,000 | Implemented |
MA0207 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $292 | $381 | Implemented |
MO0022 # 01 Y:1991 | 01 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,566 | $2,267 | Implemented |
MO0022 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,956 | $6,256 | Implemented |
MO0022 # 03 Y:1991 | 03 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,150 | $60 | Implemented |
MO0022 # 04 Y:1991 | 04 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $469 | $200 | Implemented |
MO0022 # 05 Y:1991 | 05 | 1991 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $45 | $334 | Implemented |
MO0022 # 06 Y:1991 | 06 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $262 | $0 | Implemented |
WI0112 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,926 | $153 | Implemented |
WI0112 # 02 Y:1991 | 02 | 1991 | IMPROVE LUBRICATION PRACTICES | $712 | $0 | Implemented |
WI0112 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $692 | $640 | Implemented |
WI0112 # 04 Y:1991 | 04 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $604 | $0 | Implemented |
WI0112 # 05 Y:1991 | 05 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $586 | $0 | Implemented |
WI0112 # 06 Y:1991 | 06 | 1991 | INSTALL STORM WINDOWS AND DOORS | $321 | $812 | Implemented |
WI0112 # 07 Y:1991 | 07 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $263 | $200 | Implemented |
WI0112 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $180 | $200 | Implemented |
WI0112 # 09 Y:1991 | 09 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $132 | $300 | Implemented |
WI0112 # 10 Y:1991 | 10 | 1991 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $73 | $0 | Implemented |
UD0340 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $5,952 | $2,000 | Implemented |