Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

517

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0450 # 05 Y:1991 05 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $647 $0 Not Implemented
GT0450 # 06 Y:1991 06 1991 RECOVER WASTE HEAT FROM EQUIPMENT $641 $500 Not Implemented
GT0440 # 01 Y:1991 01 1991 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $945 $500 Implemented
GT0440 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,354 $795 Implemented
GT0440 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,910 $17,250 Implemented
GT0440 # 04 Y:1991 04 1991 RECOVER WASTE HEAT FROM EQUIPMENT $3,743 $2,160 Implemented
GT0440 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,210 $650 Implemented
GT0440 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $532 $593 Implemented
GT0440 # 07 Y:1991 07 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $898 $0 Implemented
GT0440 # 08 Y:1991 08 1991 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $15,580 $70,000 Implemented
GT0432 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,719 $7,993 Not Implemented
GT0432 # 02 Y:1991 02 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $115 $443 Not Implemented
GT0432 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $610 $150 Not Implemented
GT0432 # 04 Y:1991 04 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $265 $1,200 Not Implemented
GT0432 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,830 $1,500 Not Implemented
GT0432 # 06 Y:1991 06 1991 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,770 $2,970 Not Implemented
GT0418 # 01 Y:1990 01 1990 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $31,780 $0 Not Implemented
GT0418 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,056 $666 Implemented
GT0418 # 03 Y:1990 03 1990 INSTALL SET-BACK TIMERS $178 $0 Implemented
GT0418 # 04 Y:1990 04 1990 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,850 $5,500 Implemented
GT0418 # 05 Y:1990 05 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $16,381 $132,430 Not Implemented
GT0418 # 06 Y:1990 06 1990 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $790 $770 Not Implemented
GT0418 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $921 $1,430 Implemented
GT0412 # 01 Y:1990 01 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $100 $250 Implemented
GT0412 # 02 Y:1990 02 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,550 $600 Implemented