Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0200 # 06 Y:1994 | 06 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,153 | $1,000 | n/a |
WI0200 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $360 | $450 | n/a |
AM0202 # 01 Y:1994 | 01 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $36,010 | $0 | Not Implemented |
AM0202 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,643 | $21,675 | Implemented |
AM0202 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $915 | $100 | Implemented |
AM0202 # 04 Y:1994 | 04 | 1994 | PAY UTILITY BILLS ON TIME | $608 | $0 | Not Implemented |
AM0202 # 05 Y:1994 | 05 | 1994 | USE SYNTHETIC LUBRICANT | $445 | $0 | Implemented |
AM0203 # 01 Y:1994 | 01 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $34,315 | $0 | Not Implemented |
AM0203 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,650 | $0 | Implemented |
AM0203 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $370 | Implemented |
AM0203 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $400 | $0 | Not Implemented |
GT0518 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,240 | $9,760 | Implemented |
GT0518 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $780 | $1,000 | Implemented |
GT0518 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,540 | $13,600 | Implemented |
GT0518 # 04 Y:1994 | 04 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,920 | $1,700 | Implemented |
GT0518 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $230 | $0 | Not Implemented |
GT0518 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,410 | $500 | Implemented |
GT0518 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $120 | $210 | Implemented |
GT0518 # 08 Y:1994 | 08 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,790 | $0 | Implemented |
GT0518 # 09 Y:1994 | 09 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,140 | $0 | Implemented |
GT0518 # 10 Y:1994 | 10 | 1994 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $8,800 | $35,000 | Not Implemented |
WI0199 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,320 | $1,800 | Not Implemented |
WI0199 # 02 Y:1994 | 02 | 1994 | INSTALL OCCUPANCY SENSORS | $1,834 | $825 | Not Implemented |
WI0199 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $817 | $1,276 | Implemented |
WI0199 # 04 Y:1994 | 04 | 1994 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,819 | $15,000 | Not Implemented |