Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
295
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0240 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,657 | $1,050 | Implemented |
LL0240 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $2,004 | $990 | Implemented |
LL0240 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,827 | $12,200 | Implemented |
LL0240 # 04 Y:2006 | 04 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $15,054 | $726 | Implemented |
LL0240 # 03 Y:2006 | 03 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $24,138 | $143,240 | Implemented |
LL0240 # 02 Y:2006 | 02 | 2006 | USE PHOTOCELL CONTROLS | $28,394 | $1,110 | Implemented |
LL0240 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $40,093 | $2,862 | Implemented |
LL0228 # 01 Y:2005 | 01 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $79,796 | $4,000 | Implemented |
LL0228 # 12 Y:2005 | 12 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $80,610 | $20,000 | Implemented |
LL0228 # 11 Y:2005 | 11 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $106,500 | $20,000 | Implemented |
LL0228 # 10 Y:2005 | 10 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $7,627 | $0 | Not Implemented |
LL0228 # 09 Y:2005 | 09 | 2005 | USE PHOTOCELL CONTROLS | $870 | $0 | Not Implemented |
LL0228 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,872 | $0 | Not Implemented |
LL0228 # 07 Y:2005 | 07 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,945 | $0 | Implemented |
LL0228 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $14,813 | $0 | Not Implemented |
LL0228 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,509 | $0 | Not Implemented |
LL0228 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $19,616 | $0 | Not Implemented |
LL0228 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $47,819 | $22,000 | Implemented |
LL0228 # 02 Y:2005 | 02 | 2005 | USE PHOTOCELL CONTROLS | $55,019 | $0 | Not Implemented |
LL0224 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,687 | $0 | Not Implemented |
LL0224 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $4,838 | $0 | Not Implemented |
LL0224 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,157 | $0 | Not Implemented |
LL0224 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,031 | $0 | Not Implemented |
LL0224 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,284 | $0 | Not Implemented |
LL0224 # 08 Y:2005 | 08 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $296 | $0 | Not Implemented |