Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,260
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0097 # 02 Y:1983 | 02 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $146 | $99 | Implemented |
OK0097 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,518 | $20,020 | Not Implemented |
OK0091 # 01 Y:1983 | 01 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $4,250 | $420 | Not Implemented |
OK0091 # 02 Y:1983 | 02 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $895 | $4 | Not Implemented |
OK0091 # 03 Y:1983 | 03 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $962 | $165 | Not Implemented |
OK0091 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $334 | $400 | Not Implemented |
OK0091 # 05 Y:1983 | 05 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $217 | $102 | Not Implemented |
OK0091 # 06 Y:1983 | 06 | 1983 | RECOVER WASTE HEAT FROM EQUIPMENT | $63 | $135 | Not Implemented |
OK0091 # 07 Y:1983 | 07 | 1983 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,100 | $315 | Not Implemented |
GT0175 # 01 Y:1983 | 01 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,900 | $12,800 | Not Implemented |
GT0175 # 02 Y:1983 | 02 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $1,860 | $1,000 | Not Implemented |
GT0175 # 03 Y:1983 | 03 | 1983 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,250 | $2,200 | Not Implemented |
GT0175 # 04 Y:1983 | 04 | 1983 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $737 | $1,451 | Not Implemented |
GT0175 # 05 Y:1983 | 05 | 1983 | COVER OPEN TANKS | $499 | $900 | Not Implemented |
TN0171 # 01 Y:1983 | 01 | 1983 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,000 | $13,000 | Not Implemented |
TN0171 # 02 Y:1983 | 02 | 1983 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $5,000 | $0 | Not Implemented |
TN0171 # 03 Y:1983 | 03 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,800 | $400 | Not Implemented |
OK0076 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $173 | $550 | Implemented |
OK0076 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $40 | $228 | Implemented |
OK0076 # 03 Y:1983 | 03 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $433 | $120 | Implemented |
OK0076 # 04 Y:1983 | 04 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $172 | $386 | Implemented |
OK0078 # 01 Y:1983 | 01 | 1983 | INSTALL SET-BACK TIMERS | $1,033 | $0 | Not Implemented |
OK0078 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,482 | $1,779 | Not Implemented |
OK0078 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $13,322 | $100 | Not Implemented |
OK0078 # 04 Y:1983 | 04 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,697 | $0 | Not Implemented |