Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

349

matching recommendations
Reset
SIC 3535 Conveyors And Conveying Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0039 # 05 Y:1994 05 1994 ADD AREA LIGHTING SWITCHES $1,444 $130 Implemented
SF0039 # 06 Y:1994 06 1994 OPTIMIZE PLANT POWER FACTOR $2,458 $4,153 Not Implemented
SF0039 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,811 $2,759 Implemented
OK0446 # 01 Y:1994 01 1994 REDUCE VENTILATION AIR $8,869 $22,080 Not Implemented
OK0446 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,792 $2,333 Not Implemented
OK0446 # 03 Y:1994 03 1994 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,196 $0 Implemented
OK0446 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $680 $223 Not Implemented
OK0446 # 05 Y:1994 05 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $529 $0 Implemented
OK0446 # 06 Y:1994 06 1994 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $296 $220 Not Implemented
OK0446 # 07 Y:1994 07 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $162 $0 Not Implemented
ME0110 # 01 Y:1994 01 1994 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $787 $1,250 Not Implemented
ME0110 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $368 $400 Implemented
ME0110 # 03 Y:1994 03 1994 KEEP BOILER TUBES CLEAN $357 $200 Implemented
AM0193 # 01 Y:1993 01 1993 INSTALL SKYLIGHTS $4,880 $11,100 Not Implemented
AM0193 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,750 $0 Not Implemented
AM0193 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $4,660 $7,500 Implemented
AM0193 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,110 $800 Implemented
AM0193 # 05 Y:1993 05 1993 INSTALL TIMERS AND/OR THERMOSTATS $710 $450 Not Implemented
AM0193 # 06 Y:1993 06 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $510 $1,550 Not Implemented
AM0193 # 07 Y:1993 07 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $220 $0 Implemented
AM0193 # 08 Y:1993 08 1993 PAY UTILITY BILLS ON TIME $200 $0 Not Implemented
AM0193 # 09 Y:1993 09 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $130 $195 Not Implemented
AM0193 # 10 Y:1993 10 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $115 $126 Not Implemented
WI0175 # 04 Y:1993 04 1993 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,672 $4,650 Implemented
WI0175 # 03 Y:1993 03 1993 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $2,118 $675 Not Implemented