Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
928
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0170 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,355 | $1,543 | Implemented |
TN0234 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $2,524 | $0 | Implemented |
CO0015 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $963 | $908 | Implemented |
CO0015 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $300 | $300 | Implemented |
CO0015 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $290 | $50 | Implemented |
CO0015 # 04 Y:1984 | 04 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $694 | $1,127 | Implemented |
CO0015 # 06 Y:1984 | 06 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $791 | $230 | Implemented |
CO0015 # 10 Y:1984 | 10 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,676 | $5,000 | Implemented |
CO0015 # 11 Y:1984 | 11 | 1984 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $335 | $250 | Implemented |
TN0211 # 03 Y:1984 | 03 | 1984 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,366 | $2,753 | Implemented |
TN0211 # 02 Y:1984 | 02 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,051 | $0 | Implemented |
UD0095 # 01 Y:1983 | 01 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,144 | $18,000 | Implemented |
UD0095 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $583 | $172 | Implemented |
UD0095 # 04 Y:1983 | 04 | 1983 | INSTALL STORM WINDOWS AND DOORS | $3,398 | $2,560 | Implemented |
UD0090 # 03 Y:1983 | 03 | 1983 | INSTALL STORM WINDOWS AND DOORS | $703 | $100 | Implemented |
UD0090 # 05 Y:1983 | 05 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $183 | $0 | Implemented |
UD0053 # 04 Y:1982 | 04 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,670 | $92,250 | Implemented |
KU0053 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,126 | $9,767 | Implemented |
KU0053 # 02 Y:1982 | 02 | 1982 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $24,341 | $10,000 | Implemented |
KU0053 # 03 Y:1982 | 03 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,175 | $360 | Implemented |
KU0053 # 04 Y:1982 | 04 | 1982 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,069 | $250 | Implemented |
KU0053 # 06 Y:1982 | 06 | 1982 | INSULATE BARE EQUIPMENT | $674 | $90 | Implemented |
KU0053 # 07 Y:1982 | 07 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $256 | $80 | Implemented |
KU0053 # 08 Y:1982 | 08 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,140 | $1,320 | Implemented |
KU0046 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $831 | $1,852 | Implemented |