Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 3555 | Printing Trades Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0135 # 08 Y:1994 | 08 | 1994 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $77 | $150 | Implemented |
MO0135 # 07 Y:1994 | 07 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $523 | $240 | Implemented |
MO0135 # 06 Y:1994 | 06 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,447 | $4,559 | Implemented |
MO0135 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,831 | $18,231 | Implemented |
MO0135 # 04 Y:1994 | 04 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $211 | $50 | Not Implemented |
MO0135 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $331 | $410 | Not Implemented |
MO0135 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $387 | $344 | Not Implemented |
MO0135 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,507 | $612 | Implemented |
MO0126 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $623 | $155 | Not Implemented |
MO0126 # 07 Y:1994 | 07 | 1994 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $51 | $75 | Not Implemented |
MO0126 # 06 Y:1994 | 06 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,600 | $4,200 | Not Implemented |
MO0126 # 05 Y:1994 | 05 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $600 | $295 | Not Implemented |
MO0126 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,207 | $7,456 | Not Implemented |
MO0126 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,286 | $615 | Implemented |
MO0126 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,096 | $12,303 | Implemented |
MO0073 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,242 | $1,848 | Implemented |
MO0073 # 08 Y:1992 | 08 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,250 | $1,200 | Not Implemented |
MO0073 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,490 | $275 | Implemented |
MO0073 # 06 Y:1992 | 06 | 1992 | SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY | $211 | $314 | Not Implemented |
MO0073 # 05 Y:1992 | 05 | 1992 | RECOVER AND REUSE COOLING WATER | $2,686 | $0 | Not Implemented |
MO0073 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $838 | $0 | Implemented |
MO0073 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,565 | $4,992 | Implemented |
MO0073 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,294 | $0 | Implemented |