Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsSIC | 3559 | Special Industry Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0021 # 06 Y:1995 | 06 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,041 | $552 | Implemented |
BD0021 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186 | $285 | Not Implemented |
WI0203 # 13 Y:1994 | 13 | 1994 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $2,500 | $500 | Not Implemented |
WI0203 # 12 Y:1994 | 12 | 1994 | REDUCE SCRAP PRODUCTION | $2,000 | $300 | Not Implemented |
WI0203 # 11 Y:1994 | 11 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $286 | $0 | Not Implemented |
WI0203 # 10 Y:1994 | 10 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $590 | $200 | Not Implemented |
WI0203 # 09 Y:1994 | 09 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,175 | $1,700 | Implemented |
WI0203 # 08 Y:1994 | 08 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,439 | $3,115 | Not Implemented |
WI0203 # 07 Y:1994 | 07 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $422 | $0 | Not Implemented |
WI0203 # 06 Y:1994 | 06 | 1994 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $1,974 | $0 | Not Implemented |
WI0203 # 05 Y:1994 | 05 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,743 | $2,844 | Implemented |
WI0203 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $227 | $300 | Not Implemented |
WI0203 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,102 | $2,259 | Not Implemented |
WI0203 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,768 | $4,650 | Implemented |
WI0203 # 01 Y:1994 | 01 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,689 | $1,400 | Implemented |