Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

61

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0253 # 06 Y:2004 06 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,580 $810 Implemented
UM0253 # 04 Y:2004 04 2004 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,806 $9,583 Implemented
UM0253 # 05 Y:2004 05 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,055 $1,229 Not Implemented
UM0253 # 07 Y:2004 07 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $122 $5 Implemented
UM0253 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,527 $19,692 Implemented
UM0253 # 02 Y:2004 02 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $9,810 $3,150 Implemented
UM0253 # 03 Y:2004 03 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,558 $750 Implemented
ND0277 # 08 Y:1997 08 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $402 $660 Implemented
ND0277 # 10 Y:1997 10 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $274 $0 Not Implemented
ND0277 # 01 Y:1997 01 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $10,296 $30,000 Implemented
ND0277 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,819 $14,790 Implemented
ND0277 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,691 $3,711 Implemented
ND0277 # 04 Y:1997 04 1997 INSTALL OCCUPANCY SENSORS $3,281 $1,200 Not Implemented
ND0277 # 05 Y:1997 05 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,940 $3,795 Not Implemented
ND0277 # 06 Y:1997 06 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,668 $360 Implemented
ND0277 # 07 Y:1997 07 1997 RECOVER WASTE HEAT FROM EQUIPMENT $662 $993 Not Implemented
ND0277 # 09 Y:1997 09 1997 INSTALL SKYLIGHTS $325 $623 Not Implemented
ND0277 # 11 Y:1997 11 1997 USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE $109 $38 Implemented
UM0035 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,152 $1,783 Implemented
UM0035 # 04 Y:1995 04 1995 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,138 $6,000 Not Implemented
UM0035 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $580 $600 Not Implemented
UM0035 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,840 $13,508 Implemented
ND0223 # 05 Y:1995 05 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $194 $800 n/a
ND0223 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $393 $890 n/a
ND0223 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $778 $300 n/a