Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

617

matching recommendations
Reset
SIC 3561 Pumps And Pumping Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0418 # 03 Y:1993 03 1993 INSTALL EFFICIENT RECTIFIERS $1,456 $15,000 Implemented
UD0418 # 04 Y:1993 04 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,180 $4,000 Implemented
UD0418 # 05 Y:1993 05 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $31,259 $6,000 Implemented
UD0418 # 06 Y:1993 06 1993 RECOVER AND REUSE COOLING WATER $12,300 $1,000 Implemented
AR0012 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,665 $1,170 Implemented
AR0012 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,387 $400 Implemented
AR0012 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $949 $720 Implemented
AR0012 # 04 Y:1993 04 1993 OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS $1,373 $100 Not Implemented
AR0012 # 05 Y:1993 05 1993 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $23,430 $23,250 Not Implemented
AR0012 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $1,684 $330 Not Implemented
OK0408 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,446 $1,961 Not Implemented
OK0408 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,314 $753 Not Implemented
OK0408 # 03 Y:1993 03 1993 INSULATE BARE EQUIPMENT $1,668 $3,528 Not Implemented
OK0408 # 04 Y:1993 04 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,789 $9,000 Not Implemented
WI0158 # 01 Y:1992 01 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,381 $0 Not Implemented
WI0158 # 02 Y:1992 02 1992 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,154 $0 Implemented
WI0158 # 03 Y:1992 03 1992 OPTIMIZE PLANT POWER FACTOR $3,161 $8,000 Not Implemented
WI0158 # 04 Y:1992 04 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,382 $0 Implemented
WI0158 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $663 $2,555 Implemented
WI0158 # 06 Y:1992 06 1992 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,099 $1,400 Not Implemented
WI0158 # 07 Y:1992 07 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $532 $1,800 Not Implemented
UD0353 # 01 Y:1991 01 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,492 $0 Not Implemented
UD0353 # 02 Y:1991 02 1991 RECOVER AND REUSE COOLING WATER $54,322 $0 Not Implemented
UD0353 # 03 Y:1991 03 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $29,392 $0 Not Implemented
UD0353 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,700 $0 Not Implemented