Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 3589 | Service Industry Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0236 # 06 Y:2013 | 06 | 2013 | INSTALL OCCUPANCY SENSORS | $2,284 | $400 | Not Implemented |
MI0236 # 10 Y:2013 | 10 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $784 | $4,812 | Not Implemented |
MI0236 # 07 Y:2013 | 07 | 2013 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,102 | $447 | Implemented |
MI0236 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,087 | $80 | Implemented |
MI0236 # 09 Y:2013 | 09 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $916 | $40 | Implemented |
MI0236 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,041 | $1,660 | Implemented |
MI0236 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,939 | $63,550 | Implemented |
MI0236 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,443 | $1,800 | Implemented |
MI0236 # 04 Y:2013 | 04 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $10,720 | $80 | Implemented |
MI0236 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,825 | $7,995 | Not Implemented |
MI0220 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,280 | $1,660 | Implemented |
MI0220 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,329 | $40 | Implemented |
MI0220 # 11 Y:2012 | 11 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,014 | $320 | Implemented |
MI0220 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,676 | $20,320 | Not Implemented |
MI0220 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,778 | $1,800 | Implemented |
MI0220 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,181 | $52,934 | Not Implemented |
MI0220 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,448 | $80 | Implemented |
MI0220 # 07 Y:2012 | 07 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,050 | $200 | Implemented |
MI0220 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,863 | $5,850 | Not Implemented |
MI0220 # 09 Y:2012 | 09 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,772 | $545 | Not Implemented |
MI0220 # 10 Y:2012 | 10 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $2,072 | $5,800 | Not Implemented |
MI0220 # 12 Y:2012 | 12 | 2012 | INSTALL SKYLIGHTS | $978 | $1,920 | Implemented |
MI0220 # 13 Y:2012 | 13 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $906 | $208 | Implemented |
MI0217 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $18,962 | $4,500 | Implemented |
MI0217 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,412 | $900 | Implemented |