Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,249

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0303 # 01 Y:1990 01 1990 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $2,148 $0 Implemented
UD0303 # 02 Y:1990 02 1990 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $761 $800 Implemented
UD0303 # 03 Y:1990 03 1990 RECOVER WASTE HEAT FROM EQUIPMENT $276 $400 Not Implemented
UD0303 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,496 $3,102 Implemented
UD0304 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,855 $2,800 Not Implemented
UD0304 # 02 Y:1990 02 1990 USE DEMAND CONTROLLER OR LOAD SHEDDER $867 $1,000 Not Implemented
UD0304 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,928 $4,920 Implemented
UD0304 # 04 Y:1990 04 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $332 $0 Implemented
UD0304 # 05 Y:1990 05 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,558 $1,500 Implemented
UD0304 # 06 Y:1990 06 1990 RECOVER WASTE HEAT FROM EQUIPMENT $3,648 $7,000 Not Implemented
OK0288 # 01 Y:1989 01 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,619 $300 Implemented
OK0288 # 02 Y:1989 02 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $46,349 $7,786 Implemented
OK0288 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,763 $0 Implemented
OK0288 # 04 Y:1989 04 1989 OPTIMIZE PLANT POWER FACTOR $1,035 $3,000 Not Implemented
OK0288 # 05 Y:1989 05 1989 INSTALL TIMERS AND/OR THERMOSTATS $916 $50 Implemented
UD0276 # 01 Y:1989 01 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,433 $0 Not Implemented
UD0276 # 02 Y:1989 02 1989 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,143 $0 Not Implemented
AM0045 # 01 Y:1988 01 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,838 $3,000 Implemented
AM0045 # 02 Y:1988 02 1988 TURN OFF EQUIPMENT WHEN NOT IN USE $645 $40 Implemented
AM0045 # 03 Y:1988 03 1988 ELIMINATE LEAKS IN WATER LINES AND VALVES $400 $40 Implemented
AM0045 # 04 Y:1988 04 1988 RECOVER WASTE HEAT FROM EQUIPMENT $275 $550 Not Implemented
AM0045 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $48 $32 Implemented
AM0045 # 06 Y:1988 06 1988 INSTALL TIMERS AND/OR THERMOSTATS $194 $225 Implemented
AM0045 # 07 Y:1988 07 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $145 $336 Implemented
WI0037 # 01 Y:1988 01 1988 IMPROVE LUBRICATION PRACTICES $3,862 $0 Not Implemented