Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
89
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0012 # 02 Y:1984 | 02 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,583 | $500 | Implemented |
CO0012 # 03 Y:1984 | 03 | 1984 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $409 | $600 | Implemented |
TN0221 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $967 | $0 | Implemented |
TN0221 # 04 Y:1984 | 04 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $773 | $475 | Implemented |
TN0221 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $2,849 | $10,000 | Not Implemented |
TN0221 # 02 Y:1984 | 02 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,248 | $8,600 | Not Implemented |
TN0221 # 01 Y:1984 | 01 | 1984 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $4,406 | $7,000 | Not Implemented |
CO0012 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,286 | $600 | Implemented |
CO0012 # 05 Y:1984 | 05 | 1984 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,101 | $6 | Implemented |
CO0012 # 06 Y:1984 | 06 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $16,597 | $4,000 | Implemented |
CO0012 # 08 Y:1984 | 08 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $241 | $17 | Implemented |
CO0012 # 07 Y:1984 | 07 | 1984 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $1,984 | $1,160 | Implemented |
TN0221 # 06 Y:1984 | 06 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $148 | $420 | Implemented |
TN0221 # 07 Y:1984 | 07 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $237 | $0 | Implemented |
OK0147 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $566 | $333 | Implemented |
OK0147 # 07 Y:1984 | 07 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,671 | $1,647 | Implemented |
OK0147 # 05 Y:1984 | 05 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,120 | $1,236 | Implemented |
OK0147 # 04 Y:1984 | 04 | 1984 | HEAT WATER WITH EXHAUST HEAT | $7,174 | $6,955 | Not Implemented |
OK0147 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,650 | $6,252 | Implemented |
OK0147 # 02 Y:1984 | 02 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $509 | $131 | Implemented |
OK0147 # 01 Y:1984 | 01 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,160 | $900 | Implemented |
TN0218 # 07 Y:1984 | 07 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $677 | $90 | Implemented |
TN0218 # 06 Y:1984 | 06 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $758 | $0 | Not Implemented |
TN0218 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,078 | $4,350 | Not Implemented |
TN0218 # 03 Y:1984 | 03 | 1984 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $4,352 | $3,700 | Implemented |