IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

24

matching recommendations
Reset
SIC 3613 Switchgear And Switchboard Apparatus
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0385 # 08 Y:2009 08 2009 DEVELOP A REPAIR/REPLACE POLICY $362 $499 Implemented
NC0385 # 07 Y:2009 07 2009 USE PHOTOCELL CONTROLS $213 $200 Implemented
NC0385 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $872 $1,643 Implemented
NC0385 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,555 $9,880 Implemented
NC0385 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $210 $0 Implemented
NC0385 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,705 $1,900 Not Implemented
NC0385 # 02 Y:2009 02 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,357 $500 Implemented
NC0385 # 01 Y:2009 01 2009 COMBINE UTILITY METERS $2,054 $0 Not Implemented
NC0196 # 04 Y:2000 04 2000 OPERATE DISTILLATION COLUMNS EFFICIENTLY $292 $1,100 Not Implemented
NC0196 # 07 Y:2000 07 2000 METER WASTE WATER $4,843 $15,000 Not Implemented
NC0196 # 06 Y:2000 06 2000 REVISE SMOKE CLEANUP FROM OPERATIONS $6,218 $8,400 Not Implemented
NC0196 # 05 Y:2000 05 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,438 $10,000 Implemented
NC0196 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $8,142 $5,000 Not Implemented
NC0196 # 02 Y:2000 02 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,495 $100 Implemented
NC0196 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $411 $1,080 Not Implemented
NC0157 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,968 $1,500 Not Implemented
NC0157 # 09 Y:1999 09 1999 MODIFY STARTUP/SHUTDOWN TIMES $3,193 $0 Implemented
NC0157 # 08 Y:1999 08 1999 ADD ADDITIONAL PRODUCTION SHIFT $100,000 $1,000 Not Implemented
NC0157 # 07 Y:1999 07 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $8,000 $200 Implemented
NC0157 # 06 Y:1999 06 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,015 $3,000 Implemented
NC0157 # 05 Y:1999 05 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $17,776 $20,000 Not Implemented
NC0157 # 04 Y:1999 04 1999 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $98,761 $465,000 Not Implemented
NC0157 # 03 Y:1999 03 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $6,654 $2,000 Not Implemented
NC0157 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,307 $240 Not Implemented