Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

403

matching recommendations
Reset
SIC 363 Household Appliances
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0019 # 05 Y:1985 05 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,127 $4,000 Not Implemented
TN0216 # 01 Y:1984 01 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,564 $4,000 Not Implemented
TN0216 # 02 Y:1984 02 1984 INSTALL SET-BACK TIMERS $8,300 $0 Implemented
TN0216 # 03 Y:1984 03 1984 COVER OPEN TANKS $1,096 $75 Not Implemented
TN0216 # 04 Y:1984 04 1984 COVER OPEN TANKS $273 $75 Not Implemented
TN0216 # 05 Y:1984 05 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $774 $0 Implemented
TN0216 # 06 Y:1984 06 1984 INSULATE BARE EQUIPMENT $422 $53 Not Implemented
TN0216 # 07 Y:1984 07 1984 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $112 $0 Implemented
KU0095 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,354 $2,809 Not Implemented
KU0095 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $1,064 $1,400 Not Implemented
KU0095 # 03 Y:1983 03 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,017 $1,230 Not Implemented
KU0095 # 04 Y:1983 04 1983 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $878 $4,000 Not Implemented
KU0095 # 05 Y:1983 05 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,846 $2,000 Not Implemented
KU0095 # 06 Y:1983 06 1983 INSTALL AUTOMATIC STACK DAMPER $1,323 $1,400 Not Implemented
KU0095 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $925 $378 Not Implemented
KU0095 # 08 Y:1983 08 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $682 $120 Not Implemented
KU0095 # 09 Y:1983 09 1983 USE MINIMUM SAFE OVEN VENTILATION $629 $200 Not Implemented
KU0095 # 10 Y:1983 10 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $127 $0 Not Implemented
GT0186 # 01 Y:1983 01 1983 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $10,060 $25,100 Not Implemented
GT0186 # 02 Y:1983 02 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,720 $18,880 Not Implemented
GT0186 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,511 $6,189 Not Implemented
GT0186 # 04 Y:1983 04 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,261 $500 Not Implemented
TN0148 # 01 Y:1982 01 1982 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $2,200 $65,000 Implemented
TN0148 # 02 Y:1982 02 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $400 $1,000 Not Implemented
TN0148 # 03 Y:1982 03 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $420 $1,260 Not Implemented