Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

72

matching recommendations
Reset
SIC 3695 Magnetic And Optical Recording Media
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0409 # 05 Y:1998 05 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,690 $2,500 n/a
CO0409 # 06 Y:1998 06 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $260 $0 n/a
CO0409 # 07 Y:1998 07 1998 INSTALL AN UNINTERUPTABLE POWER SUPPLY $234,000 $4,800 n/a
CO0409 # 08 Y:1998 08 1998 CLEAR AND RENT EXISTING SPACE $208,000 $-173,400 n/a
CO0409 # 09 Y:1998 09 1998 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $139,200 $9,200 n/a
CO0409 # 01 Y:1998 01 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $640 $600 n/a
OK0501 # 06 Y:1996 06 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,678 $10,815 Not Implemented
OK0501 # 01 Y:1996 01 1996 UPGRADE CONTROLS ON COMPRESSORS $7,290 $2,800 Implemented
OK0501 # 02 Y:1996 02 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,133 $0 Implemented
OK0501 # 03 Y:1996 03 1996 USE MINIMUM STEAM OPERATING PRESSURE $3,659 $0 Implemented
OK0501 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $816 $2,570 Not Implemented
OK0501 # 05 Y:1996 05 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,117 $1,957 Not Implemented
OK0501 # 07 Y:1996 07 1996 DISTILL CONTAMINATED SOLVENTS FOR REUSE $340,445 $198,500 Not Implemented
KG0018 # 05 Y:1995 05 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $89 $15 Not Implemented
KG0018 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $307 $195 Not Implemented
KG0018 # 03 Y:1995 03 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $370 $0 Not Implemented
KG0018 # 02 Y:1995 02 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,356 $450 Not Implemented
KG0018 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,874 $699 Not Implemented
WI0194 # 13 Y:1993 13 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $390 $700 Not Implemented
WI0194 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,065 $2,458 Not Implemented
WI0194 # 03 Y:1993 03 1993 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $10,533 $36,000 Not Implemented
WI0194 # 01 Y:1993 01 1993 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $22,197 $48,000 Not Implemented
WI0194 # 02 Y:1993 02 1993 INSULATE BARE EQUIPMENT $11,890 $147 Not Implemented
WI0194 # 05 Y:1993 05 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $195 $0 Not Implemented
WI0194 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,942 $3,770 Not Implemented