Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,504
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0428 # 10 Y:2023 | 10 | 2023 | INSTALL OCCUPANCY SENSORS | $1,117 | $816 | Implemented |
MI0428 # 11 Y:2023 | 11 | 2023 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $898 | $98 | Implemented |
UW2311 # 01 Y:2023 | 01 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,427 | $15,722 | Implemented |
UW2311 # 02 Y:2023 | 02 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,668 | $83,148 | Implemented |
UW2311 # 03 Y:2023 | 03 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $2,080 | Implemented |
UW2311 # 04 Y:2023 | 04 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $112,574 | $693,588 | Implemented |
UW2311 # 05 Y:2023 | 05 | 2023 | OPTIMIZE PLANT POWER FACTOR | $11,250 | $49,905 | Implemented |
UL2309 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,305 | $2,688 | Implemented |
UL2309 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $957 | $1,596 | Implemented |
UL2309 # 03 Y:2023 | 03 | 2023 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,637 | $0 | Implemented |
UL2309 # 04 Y:2023 | 04 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,370 | $18,360 | Implemented |
UL2309 # 05 Y:2023 | 05 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $194,066 | $1,198,885 | Not Implemented |
UL2309 # 06 Y:2023 | 06 | 2023 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,607 | $1,000 | Not Implemented |
UL2309 # 07 Y:2023 | 07 | 2023 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,813 | $15,000 | Not Implemented |
UL2308 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,167 | $30,537 | Not Implemented |
UL2308 # 02 Y:2023 | 02 | 2023 | INSTALL OCCUPANCY SENSORS | $2,423 | $1,362 | Not Implemented |
UL2308 # 03 Y:2023 | 03 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,994 | $2,560 | Not Implemented |
UL2308 # 04 Y:2023 | 04 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $135,738 | $1,570,854 | Not Implemented |
UL2308 # 05 Y:2023 | 05 | 2023 | OPTIMIZE PLANT POWER FACTOR | $109,084 | $64,636 | Not Implemented |
UL2308 # 06 Y:2023 | 06 | 2023 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $8,204 | $36,450 | Not Implemented |
UL2308 # 07 Y:2023 | 07 | 2023 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,871 | $15,000 | Not Implemented |
UW2310 # 01 Y:2023 | 01 | 2023 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $29,254 | $128,809 | Not Implemented |
UW2310 # 02 Y:2023 | 02 | 2023 | UPGRADE OBSOLETE EQUIPMENT | $153,154 | $859,050 | Not Implemented |
UW2310 # 03 Y:2023 | 03 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,425 | $1,000 | Implemented |
UW2310 # 04 Y:2023 | 04 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,210 | $16,378 | Implemented |