Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,491
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0133 # 05 Y:1984 | 05 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,567 | $1,589 | Implemented |
KU0133 # 06 Y:1984 | 06 | 1984 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $4,813 | $2,800 | Implemented |
KU0133 # 07 Y:1984 | 07 | 1984 | IMPROVE LUBRICATION PRACTICES | $3,302 | $1,950 | Not Implemented |
KU0133 # 08 Y:1984 | 08 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,626 | $0 | Implemented |
KU0133 # 09 Y:1984 | 09 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $1,231 | $3,300 | Implemented |
KU0133 # 10 Y:1984 | 10 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,584 | $2,900 | Implemented |
KU0133 # 11 Y:1984 | 11 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,316 | $450 | Implemented |
KU0133 # 12 Y:1984 | 12 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,130 | $113 | Implemented |
KU0133 # 13 Y:1984 | 13 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,562 | $0 | Implemented |
KU0133 # 14 Y:1984 | 14 | 1984 | INSULATE BARE EQUIPMENT | $669 | $400 | Implemented |
KU0133 # 15 Y:1984 | 15 | 1984 | INSULATE BARE EQUIPMENT | $626 | $450 | Implemented |
KU0133 # 16 Y:1984 | 16 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $378 | $0 | Implemented |
KU0133 # 17 Y:1984 | 17 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $365 | $144 | Implemented |
KU0133 # 18 Y:1984 | 18 | 1984 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $245 | $250 | Implemented |
UD0042 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,309 | $1,610 | Implemented |
UD0042 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,870 | $1,450 | Implemented |
UD0042 # 03 Y:1982 | 03 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $6,580 | $139 | Implemented |
UD0042 # 04 Y:1982 | 04 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,997 | $0 | Implemented |
UD0042 # 05 Y:1982 | 05 | 1982 | REDUCE GLAZED AREAS IN BUILDINGS | $1,633 | $3,410 | Implemented |
UD0042 # 06 Y:1982 | 06 | 1982 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $866 | $4,000 | Implemented |
UD0028 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $828 | $482 | Implemented |
UD0028 # 02 Y:1982 | 02 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,052 | $0 | Implemented |
UD0028 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $205 | $400 | Not Implemented |
UD0028 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $516 | $250 | Implemented |
KU0034 # 01 Y:1982 | 01 | 1982 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $6,130 | $6,000 | Not Implemented |